SM103 

DOOR/WINDOW DETECTOR 

 
The Door/Window Detector is a Z-Wave

TM

 enabled device and is fully compatible 

with any Z-Wave

TM

 enabled network. Z-Wave

TM

 enabled devices displaying the 

Z-Wave

TM

 logo can also be used with it regardless of the manufacturer, and ours 

can also be used in other manufacturer’s Z-Wave

TM

 enabled networks.    Inclusion 

of this Door/Window Detector on other manufacturer’s Wireless Controller menu 
allows remote turn-on of connected modules and their connected lighting when the 
Detector is triggered. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Include to or Exclude from a Z-Wave

TM

 Network   

 
In the rear casing, there is a tamper switch which is used to carry out inclusion, 
exclusion or reset.  When power is first applied, its LED flashes on and off 
alternately and repeatedly at 2-second intervals.  It implies that it has not been 
assigned a node ID and cannot work with Z-Wave enabled devices.    The Detector 
will stay “awake” for 10 minutes when power is first applied to allow time for 
configuration.  Please get familiar with the terms below before starting the 
operations.   

 

Function

 

Description

 

Inclusion 

 

Add a Z-Wave enabled device (e.g. Detector) to Z-Wave network.

 

Exclusion 

 

Delete a Z-Wave enabled device (e.g. Detector) from the network.

 

Association 

 

After inclusion, you have to define the relationship between devices. 
Trough association, device can be assigned as master/slave, and specify 
which slave is going to be controlled by which master.

 

Reset

 

Restore Detector to factory default.

 

 
The table below lists an operation summary of basic Z-Wave functions.  Please 
refer to the instructions for your Z-Wave

TM

 Certificated Primary Controller to access 

the setup function, and to include/exclude/associate devices.   

 

Function Description 

LED 

Indication 

No node ID 

The Z-Wave Controller does not allocate 
a node ID to the unit. 

2-second on, 2-second 
off 

1.  Have Z-Wave Controller entered 

inclusion mode. 

Inclusion 

2.    Pressing tamper switch three times 

within 1.5 second will enter inclusion 
mode. 

 

1.  Have Z-Wave Controller entered 

exclusion mode. 

Exclusion 

2.  Pressing tamper switch three times 

within 1.5 second will enter 
exclusion mode. 

LED lights up once 
whenever tamper switch 
is pressed once. 

1.  Press tamper switch three times 

within 1.5 second. 

 

2.  Within 1 second, press and hold the 

tamper switch until LED is off. 

LED keeps on before 
reset function has been 
completed. 

Reset 

3.  IDs are excluded and all of preset 

value will be reset to factory default.

2-second on, 2-second 
off 

1.    Have Z-Wave Controller entered 

association mode. 

 

Association 

2.    When pressing tamper switch three 

times within 1.5 second, the unit will 
emit the NIF which implies that the 
unit has entered association mode. 

 

Ú

Including a node ID allocated by Z-Wave Controller means inclusion.    Excluding a node 
ID allocated by Z-Wave Controller means exclusion. 

Ú

Failed or success in including/excluding the node ID can be viewed from the Z-Wave 

Controller.

 

 
 

Tamper Switch