1.2 Door sensor alarm information and connection 

The product supports 2 connection groups, group 1 support one device to receive alarm information, group 2 supports 

two devices, when the door sensor triggered, then send out “BASIC SET” command to control the device in group 2.   

 

1.3 Factory reset 

Press the tamper switch 6 times repeatedly in 2 seconds to restore the factory setting. 

 

1.4 Activated Operation 

a)

 

Manually activation 

Press the tamper switch one time quickly, the device sends out the activated information automatically, and have 

10s to receive the gateway setting information after activated. 

b)

 

Automatically activation 

 

    The device automatically activates every 24 h as default, and has 10 s to receive the gateway setting information,   

the max value of report time is 120h, the minimum value of report time is 30 minutes.   

 

V. ZWAVE report information       

1. Group 1 

a) The sensor status report: Binary Sensor Report 

When the sensor triggered or return to normal, it will send “Binary Sensor Report” Command to the device in group 1. 

When the magnetic sensor alarming: 

[Command Class Sensor Binary

Sensor Binary Report, Value = 0xFF,Type =0x0A (Door/Window)] 

When the magnetic sensor return to normal: 

[Command Class Sensor Binary

Sensor Binary Report, Value = 0x00,Type =0A (Door/Window)] 

 

b) Tamper event report: Sensor Binary Report 

It will send “Sensor Binary Report” command to the device in group one when the anti tamper switch of the sensor 

dismantled. 

Anti-tamper returns to normal status (press the tamper switch and last 5s)   

[Command Class Sensor Binary

Sensor Binary Report, value = 0x00,type =08(Tamper)] 