1
6
Other Setup Options through Configuration
Functions
Paramete
r
Number
Parameter Value
Size
( bytes)
Learn IR code
25 (0x19)
Default: 0x0000
range: (0x0000 to 0x20)
refer to learning mapping table
2
Check IR
Code
Learning
Status
(Read Only)
26(0x1A)
Default: 0x00
range: 0 to 4 (0x00 to 0x04)
0(0x00) : Idle - IR Channel is
idle
1(0x01) : OK - the last learning
opera- tion was completed
successfully 2(0x02) : Learning -
ZXT-510 is busy processing
previous learning request 3(0x03) :
Full
– All locations are being used.
4(0x04) : The last learning
request was failed
Note:The status value 0x01 and
0x04 will be reset to 0x00 after
ZXT-510
receives
a
get
command to this pa- rameter.
1
Set IR Code
number
from built-in
code library
27 (0x1B)
Refer to Code Finder Webpage.
2