Notes:
1. It is recommended to perform the Remove (Exclude)
procedure before per- forming an Add (Include) procedure.
2. Red Indicator flashes TWICE then stay off to represent the
Add / Remove pro- cess failed, please repeat the above
step again.
3. If the Add (Include) process fails, try Remove (Exclude) and
/or resetting the AC Master to Factory Default and repeat
the above step.
Step 3 Setup Automatic Status Report Association to
Gateway
Please consult your Gateway suppiler for more detail. Normally,
User can ignore this step during the setup.
ZXT-510 supports 1 association group
Association Group #1
Association Group #1 (max. 1 node) is default to associate
with the primary controller (Gateway/Hub/Controller) for AC
Master Status change report, refer to below for report details:
• Current Room Temperature (report in precision of 0.5°C or
1°F) (It will be according to Configuration Parameter 39
setting to decide the trigger level)
• Current Battery Level (Only apply in Low Battery Warning
hap- pened)
• Device Reset Locally Notification (Only report when the AC
Master has been triggered the RESET TO DEFAULT)
Step 4 Setup Air Conditioner IR code
• The UI of set up the IR code varies from different gateways. If
gate- ways have dedicated UI for the IR code setup please
refer to the gateway UI and ignore the below steps.
• If your gateway does not have dedicated UI for ZXT-510 IR
code setup, but support Z-Wave thermostat Command Class