YZ Systems, Inc. • 3101 Pollok Drive • Conroe, Texas • USA • 77303 • P: 936.788.5593 • F: 936.788.5720
Page 53
NJEX 8300 ver.092001 ATEX Rev.
SSSSS
ECTION
ECTION
ECTION
ECTION
ECTION
9: S
9: S
9: S
9: S
9: S
ETTING
ETTING
ETTING
ETTING
ETTING
& T
& T
& T
& T
& T
ESTING
ESTING
ESTING
ESTING
ESTING
A
A
A
A
A
LARMS
LARMS
LARMS
LARMS
LARMS
Or
Or
Setting Alarm Out Status
Alarm outputs can be configured to enable or disable
which alarms deactivate the alarm output contact
located on
TB1
, terminals
#17
and
#18,
refer to the
Wiring Control Document on page 117 in Appendix D.
Only an entire alarm area may be disabled for example,
pump alarms.
CA
CA
CA
CA
CAUTION:
UTION:
UTION:
UTION:
UTION:
Alarm outputs are critical for monitoring system perfor-
mance. Outputs should not be disabled except for
testing/troubleshooting.
Choose
*Set
in the main menu,
figure 153
.
Choose
*Par
– parameters in the Set Selection menu,
figure 154
.
Choose
*Flow
or
*Time
in the Set Parameters menu,
figures 155.
Choose
*Alarm
from the Proportional-to-Time or
Proportional-to-Flow menu,
figure 156.
Choose
*Set
from the Alarm Out Status menu,
figure
157.
To set the pump alarm status,
figure 158,
press and
release the
Select
key. The entered value will flash
when it is chosen. Use the
Down Arrow
or
Up Arrow
keys to change the setting. Press the
Enter
key to load
the entry into memory. The display will stop flashing
when the entered value is loaded into the memory.
Press the
Down Arrow
key to advance to the next
parameter.
To set the battery alarm status,
figure 159,
press and
release the
Select
key. The entered value will begin to
flash when chosen. Use the
Up Arrow
or
Down Arrow
keys to change the value. When a new value has been
chosen, press the
Enter
key to store the new value into
memory. The entered value will stop flashing when it
has been loaded into memory. Press the
Down Arrow
key to advance to the next parameter.
Or
pmp bat vmtr sig tnk
Proportional to Flow
*Set *Alarm * Esc
pmp bat vmtr sig tnk
Proportional to Time
*Set *Alarm * Esc
Figure 153
pmp bat vmtr sig tnk
PropFlow Idle
*Strt *Dsp *Set
pmp bat vmtr sig tnk
Set Selection
*Par *Cal *Esc
pmp bat vmtr sig tnk
Set Parameters
*Flow *Time *Esc
pmp bat vmtr sig tnk
Alarm Output Status
*Set *Test *Esc
Select
Enter
pmp bat vmtr sig tnk
Pump Alarm
Enabled
pmp bat vmtr sig tnk
Pump Alarm
Disabled
pmp bat vmtr sig tnk
Battery Alarm
Enabled
pmp bat vmtr sig tnk
Battery Alarm
Disabled
Select
Enter
Figure 154
Figure 155
Figure 156
Figure 157
Figure 158
Figure 159