Testing Alarm Out Status
refer to the Wiring Control Document on page
. You may test the alarm output in
general by choosing the Alarm SwitchTest option
below, figure 164-165, or you may choose to
Simulate specific alarms as illustrated in this section
as well.
Choose *Set in the main menu, figure 159.
Choose *Par – parameters in the Set Selection menu,
figure 160.
Choose *Flow or *Time in the Set Parameters menu,
figure 161.
Choose *Alarm from the Proportional-to-Time or Flow
menus, figure 162.
Choose *Test from the Alarm Out Status menu,
figure 163.
Choose *SW in the Switch / Simulation menu, figures 164.
To activate the Alarm Test Switch, figures 165,
press
and release the Select key. The entered value will flash
when it is chosen. Use the Down Arrow or Up Arrow
keys to change the setting. ON / Relay Open indicates
the alarm relay is in the test mode. OFF / Relay Closed
indicates the relay is in the normal mode. Press the
Enter key to load the entry into memory. When the unit
is in the Alarm Test Mode, a bright red light will flash in
the alarm light indicator located just below the SELECT /
ENTER switch. The display will stop flashing when the
entered value is loaded into the memory. Press the Up
Arrow key to advance to return to the Switch / Simula-
tion menu.
Choose *Sim in the Switch / Simulation menu. Any time
an alarm is simulated or real, a bright red light will flash
in the alarm light indicator located just below the SE-
LECT / ENTER switch. Any time a Non-Alarm is simu-
lated or real, a bright green light will flash in the
indicator light indicator located just below the Down Arrow key.
Or
pmp bat vmtr sig tnk
Proportional to Flow
*Set *Alarm * Esc
pmp bat vmtr sig tnk
Proportional to Time
*Set *Alarm * Esc
Figure 159
pmp bat vmtr sig tnk
PropFlow Idle
*Strt *Dsp *Set
pmp bat vmtr sig tnk
Set Selection
*Par *Cal *Esc
pmp bat vmtr sig tnk
Set Parameters
*Flow *Time *Esc
pmp bat vmtr sig tnk
Alarm Output Status
*Set *Test *Esc
Figure 160
Figure 161
Figure 162
Figure 163
pmp bat vmtr sig tnk
Switch / Simulation
*Sw *Sim *Esc
pmp bat vmtr sig tnk
Alarm Switch Test
ON / Relay Open
pmp bat vmtr sig tnk
Alarm Switch Test
Alarm Relay Closed
Figure 164
Figure 165
Figure 165