YZ Systems, Inc. 3101 Pollok Drive Conroe, Texas USA 77303 P: 936.788.5593 F: 936.788.5720
Page 5
DP-2010 TP ver.10012004
S
ECTION
2: S
YSTEM
I
NSTALLATION
Standard System Components
Standard primary components of the DynaPak 2010
include the following:
System Enclosure
,
figure 1 & 2
. Houses the
Sample Pump, Filter Regulator, Solenoid, Spun
Cylinder Sample Vessel, Catalytic Heater, and
Temperature Guage.
Sample Pump,
figure 2
. Probe mounted, pneumati-
cally actuated DP-2000 Sample Pump
.
Filter Regulator,
figure 2
. Stainless Steel requlator capable
of reducing pressure from line pressure of up to 1500 psi
down to system supply pressures in one step.
Low Power Solenoid,
figure 2
. provides interface
between the Z-65 Electronic Controller, and the Pump
Pneumatic actuation
.
Z-65 Controller Enclosure,
figure 1,
Provides a
weathertight enclosure for the Z-65 controller.
Z-65 Controller.
figure 1
. Provides
control functions
for the DynaPak Sampler in Proportional-To-Flow,
or Proportional-To-Time Modes.
figure 1
SV
L
figure 2
Enclosure Internal
Temperature Guage
Z-65 Controller
Enclosure
System Enclosure
Electric Heater
Junction
Enclosure
DP-2000 Sample Pump
Filter Regulator
Low Power Solenoid
SV
L
(CEVQT[
5[UVGO
#RRTQXGF
/WVWCN
Customer Supplied
Sample Probe
Summary of Contents for DynaPak DP-2010TP