background image

08

10

11

09

YT-1
Infrared Thermometer

User Manual And Technical Instruction

Please read the user manual carefully and follow the instructions 

before use. For date of manufacture,  please refer to the packing.

14. Warranty card

Warranty card

Product name:

 Infrared thermometer

Model:

YT-1

JIANGSU YUYUE MEDICAL EQUIPMENT & SUPPLY., LTD.

Manufacturing Address: YunYang Industrial Park 

DanYang,  Jiangsu Province, P.R. China, 212300

http://www.yuwell.com

Revision date:03MAR20

12. Product warranties

1. The thermometer is initially calibrated at the time 
of manufacture.If at any time
Youquestion the accuracy of temperature 
measurements, please contact customer service.
2.This product provides free maintenance service 
for one year. If you need to provide circuit diagram,  
necessary materials and maintenance of electrical 
circuit for any problem,  please contact the 
manufacturer.
3. No free warranty service will be provided for the 
faults caused by the following users:
1) failure caused by unauthorized disassembly and 
modification of products.
2) failure caused by product drop.
3) failure caused by failure to operate according to 
the instructions.
4)failure caused by lack of reasonable mainte-
nance.
5) damage caused by external force.
4.This product will not cause allergic reaction and 
harm to human body during normal use.

13. Electromagnetic compatibility
 information

Table 1-Compliance information for Emission test

Emission test 

Compliance 

Group 1

RF emissions 

CISPR 11

RF emissions 

CISPR 11

Class B

Immunity
test

Compliance
level

Electrostatic
disc harge
(ESD)
IEC 61000-4-2

Power frequency(50Hz)
magnetic field
IEC 61000-4-8

±8 kV contact
±15 kV air

30A/m
50Hz or 60Hz

Radiated RF EM fields
IEC 61000-4-3

10 V/m
80 MHz to 2.7 GHz
80% AM at 1kHz

Table  3-Test  specifications  for  ENCLOSURE 
PORT IMMUNITY to RF wireless communications
 equipment

There is the potentia risk of radio frequency 
interference between the device and other
devices. If there is,  please find out the problems 
and take the following measures:
(1) Turn off the device,  and turn on again.
(2) Change the direction of the device.
(3)Keep the product away from the interferential 
devices.

Table 2-Compliance information for Immunity test

 Test
frequency
 (MHz)

Band

a)

(MHz)

Service

a)

Modulation

b)

704-787

450

385

800-960

380-390

430-470

TETRA 400

GMRS 460, 

 FRS 460 

LTE Band 

13,17

GSM 800/900, 

TETRA 800, 

iDEN 820, 

CDMA 850, 

LTE Band 5

710

745

780

810

870

930

Pulse

modulation

b)

 18 Hz

FM

±5 kHz 

deviation

 1 kHz sine

Pulse

modulation

b)

 217 Hz

Pulse

modulation

b)

 18 Hz

 Test
frequency
 (MHz)

Maximum
 power
 (MHz)

Distance

 (m)

 IMMUNITY

TEST LEVEL

 (V/m)

450

385

5240

5500

5785

710

745

780

810

870

930

1720

1845

1970

2450

5100-5800 WLAN 802.11

a/n

5240

5500

5785

Pulse

modulation

b)

217 Hz

1,8

2

0,3

0,3

27

28

0,2

0,3

 9

2

0,3

28

2

0,3

 28

 0,2

0,3

9

2

0,3

 28

NOTE If necesary to achieve the IMMUNITY TEST 
LEVEL,  the distance between the transmitting 
antenna and the ME EQUIPMENT or ME SYSTEM 
may be reduced to 1 m. The 1 m test distance is 
permitted by IEC61000-4-3.

  displayed,    Replace  with  2  new  AAA  batteries  , 
slide  open  the  battery  cover  and  remove  old 
batteries.Replace the batteries being sure to align 
properly  as  indicated  inside  the  battery  compart-
ment. 
2.Remove  the  battery  from  the  product  if  it  is  not 
required  for  extended  periods  of  time  in  order  to 
avoid damage to the thermometer resulting from a 
leaking battery.
3.To  protect  the  environment,  dispose  of  empty 
batteries at appropriate collection sites according 
to national or local regulations.

         Portable RF communications equipment
(including peripherals such as antenna cables and 
external antennas) should be used no closer than 
30 cm (12 inches) to any part , including cables 
specified by the manufacturer. Otherwise,  
degradation of the performance of this equipment 
could result.
        This equipment might not offer adequate
protection to radio-frequency communication
services. The user might need to take mitigation 
measures,  such as relocating or re-orienting the 
equipment.
        When the instrument is in use, never put it near 
other instruments or stack it on other
instrument.if you have to put it near other 
Instrument or stacked other
instruments, please inspect and verify if the 
instrument could run normally.

1.Battery replacement: When "    " symbol is

1700-1990

2400-2570

GSM 1800;

TETRA 1900;

GSM 1900;

DECT;

LTE Band 1, 3, 

4, 25; UMTS

Bluetooth, 

WLAN, 

802.11 b/g/n

RFID 2450, 
LTE Band 7

1720

1845

1970

2450

Pulse

modulation

b)

217 Hz

Pulse

modulation

b)

217 Hz

a) For some services, only the uplink frequencies 
are
 included.
b) The carrier shall be modulated using a 50% duty 
cycle square wave signal.
c) As an alternative to FM modulation, 50% pulse 
modulation at 18 Hz may be used because while it 
does not represent actual modulation, it would be 
worst case.

1730207-0A

Summary of Contents for YT-1

Page 1: ...n None 2 Device structure and composition 1 Device use and applicant scope LCD area Appendix Instructions 2 AAA Alkaline Batteries Device main structure and composition The thermometer consists of a housing asensor a display and a circuit board temperature probe ranging probe power on measurement button prompt tone key battery cover LCD display area battery reminder distance unit temperature unit ...

Page 2: ...e fire to avoid the battery explosion Do not use the battery when it leaks or molds when discarding batteries or this product it should be following local regulations to avoid contamination 7 This product contains sensitive electronic compo nents should avoid strong electromagnetic interfer ence 8 Do not modify this equipment without the authori zation of the manufacturer which may lead to measure...

Page 3: ...t contains batteries and recyclable electronic waste To protect the environment do not dispose of it in the household waste but take it to appropriate local collection points Setting measure unit In the shutdown state long press the staring measuring button for 10 seconds to enter the temperature unit conversion state and then short press the staring measuring button to select and temperature unit...

Page 4: ... displayed on the screen please close to the subject as the picture shown at right When the measurement distance is less than about 5 cm the device will automatically measure after the measurement it will vibrate and have di sound and measurement result will be displayed When temperature is 37 6 99 7 or higher the device will make quick continuous three time di di di alarm sound when the measured ...

Page 5: ...g methods otherwise it may cause lens surface of senor abrasion or machine malfunction Disinfection of the product and its head Gently wipe the surface of the product and the head used for measurement with a cotton swab dipped in a little medical alcohol 70 it can be used until the alcohol has completely evaporated Precaution for storage This product should be stored in a dust free dry place pleas...

Page 6: ... electronics devices according to Directive 2002 96 EC IP22 EC REP Temperature range Humidity range Atmospheric pressure range This side up Fragile Non rainproof Prevent the invasion of solid objects larger than 12mm When the lamp is tilted 15 degrees it can still prevent the invasion of dripping water When the lamp is tilted to 15 degrees from the vertical Angle the dripping water will not cause ...

Page 7: ...n the presence of flammable anesthetic gases mixed with air or oxygen or nitrous oxide Product size 149 38 42 mm Product weight about 68g not including cell service life 5years The clinical thermometer is a direct mode Battery replacement cycle use the new battery for no less than 3000 measurements 9 Product technical parameters 11 Replacing the batteries The normal body temperature of people is a...

Page 8: ...product drop 3 failure caused by failure to operate according to the instructions 4 failure caused by lack of reasonable mainte nance 5 damage caused by external force 4 This product will not cause allergic reaction and harm to human body during normal use displayed Replace with 2 new AAA batteries slide open the battery cover and remove old batteries Replace the batteries being sure to align prop...

Page 9: ... communications equipment including peripherals such as antenna cables and external antennas should be used no closer than 30 cm 12 inches to any part including cables specified by the manufacturer Otherwise degradation of the performance of this equipment could result This equipment might not offer adequate protection to radio frequency communication services The user might need to take mitigatio...

Page 10: ...Compliance information for Immunity test Test frequency MHz Banda MHz Servicea Modulationb 704 787 450 385 800 960 380 390 430 470 TETRA 400 GMRS 460 FRS 460 LTE Band 13 17 GSM 800 900 TETRA 800 iDEN 820 CDMA 850 LTE Band 5 710 745 780 810 870 930 Pulse modulationb 18 Hz FM 5 kHz deviation 1 kHz sine Pulse modulationb 217 Hz Pulse modulationb 18 Hz 1700 1990 2400 2570 GSM 1800 TETRA 1900 GSM 1900 ...

Page 11: ...cesary to achieve the IMMUNITY TEST LEVEL the distance between the transmitting antenna and the ME EQUIPMENT or ME SYSTEM may be reduced to 1 m The 1 m test distance is permitted by IEC61000 4 3 a For some services only the uplink frequencies are included b The carrier shall be modulated using a 50 duty cycle square wave signal c As an alternative to FM modulation 50 pulse modulation at 18 Hz may ...

Page 12: ...14 Warranty card Warranty card Product name Infrared thermometer Model YT 1 ...

Page 13: ...YT 1 Infrared Thermometer User Manual And Technical Instruction Please read the user manual carefully and follow the instructions before use For date of manufacture please refer to the packing ...

Page 14: ...JIANGSU YUYUE MEDICAL EQUIPMENT SUPPLY LTD Manufacturing Address YunYang Industrial Park DanYang Jiangsu Province P R China 212300 http www yuwell com Revision date 03MAR20 1730207 0A ...