1.Principle of Leeb hardness testing method 

The  impact  body,  which  is  equipped  with  tungsten  carbide,  impacts  into  the 

work  piece  and  rebounds  back.  The  rebound  and  impact  velocities  are 

measured  at  the  1mm  point  from  the  work  piece  in  the  following  way:    the 

integrated  permanent  magnet  will  produce  directly  proportional  voltage  with 

the impact velocity. The Leeb hardness values are calculated by the following 

formula:   

   

 

 

HL=1000×( V

/ V

In Which

 

HL: Leeb hardness values 

 

 

V

b

 : the voltage produced during the rebound of impact body 

 

 

V

a

 : the voltage produced during the impact of impact body 

Figure 1 shows the voltage produced during the impact and rebound of impact 

body:

 

Figure 1    voltage features of output signal 

 

 

 

 

 

 

 

 

 

The  Leeb  hardness  values  can  be  converted  to  other  hardness  scales  directly, 

such as HV, HRC, HRB, HB and HS. 

 

 

 

2. Summary   

2.1 LM-100 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1                                                                                                                                                        2 

Summary of Contents for LM-100

Page 1: ...nts 8 4 1 2 Weight and Thickness Requirements 8 4 1 3 Surface Hardened Layer 8 4 1 4 Curved surface Requirement 8 4 2 Support of Test piece 9 5 Operation 9 5 1 Display 9 5 2 Keyboard 10 5 3 Turn on th...

Page 2: ...l voltage with the impact velocity The Leeb hardness values are calculated by the following formula HL 1000 Vb Va In Which HL Leeb hardness values Vb the voltage produced during the rebound of impact...

Page 3: ...n carbide Tungsten carbide Tungsten carbide Tungsten carbide Impact Device Diameter 20mm 20mm 20mm 30mm 20mm Impact Device Length 86 147 75mm 162mm 141mm 254mm 155mm Impact Device Weight 50g 80g 75g 2...

Page 4: ...uitcase 2 6 Optional accessories Impact device DC C DL D 15 G Standard Calibration Test Block Blue tooth module Thermal Printer Standard supporting ring Small Supporting ring Special supporting rings...

Page 5: ...s Mould cavity Heavy workpieces Failure analysis of pressure vessel turbine and other equipments Small test area The production line of Bearings and other parts Distinguish the material of the metal m...

Page 6: ...f a large weight and thickness may still cause deformation so reinforcement and support in the rear surface of the test point is necessary 5 Operation 5 1 Display 5 2 Keyboard 5 3 Turn on the instrume...

Page 7: ...irmly on the surface of the sample the impact direction should be vertical to the testing surface Press the release button on the upside of the impact device to test The sample and the impact device a...

Page 8: ...the Thermal Printer then the groups testing data will be printed 5 9 Calibration Error correction settings Measuring error can be usually caused by test tip abrasion or changing another impact device...

Reviews: