ST950S Plus+ Installation and Commissioning Manual
The design takes RAG node aspect drives and simulates an ELV far side pedestrian red and green
aspect drive that is then passed to the standard PCaTS unit.
Figure 56. PCATS Adaptor Board
4.10.4. Parts
PLUS+ HELIOS PCaTS KIT and ASSY 667/1/53129/000
4.11. Smartloop
The Smartloop is normally fitted within ‘access chambers’ that are positioned in the most convenient
positions, close to where the inductive loops are to be installed.
The Smartloop provides an interface that allows for further Smartloops to be installed downstream. The
connection(s) is made to PL1on the RAG node, via the terminal block located with the PTB, see section
.
There are three variants of the Smartloop, to reflect the main ranges of loop inductances that are
normally encountered. However, in most situations it is expected that variant /001 will be the correct
default variant to be selected.
Page 98