CLM920_RC3(RV3 RE3)LCC Series CAT1 Module Hardware Manual
Shanghai YUGE Information Technology Co., Ltd.
- 56 -
Parameter
Min
Typical
Max
VBAT_BB
VBAT_RF
3.3V
3.7V
4.2V
The power-on time of any interface of the module should not be earlier than the power-on
time of the module, otherwise it may cause the module to be abnormal or damaged.
5.5 Static characteristics
The internal design of CLM920_RC3 module has been considered and corresponding ESD
protection has been considered, but ESD problems may also occur in the production
assembly and experimental testing of the module, so application developers need to consider
the ESD protection of the final product.
In addition to the recommended circuit of the interface design of the reference document, the
customer also needs to pay attention to the following points when designing:
The PCB layout of the protection device should try to follow the "V" line and avoid the "T"
line.
The ground plane around the module guarantees integrity and should not be split.
In the process of module production, assembly and laboratory testing, it is necessary to pay
attention to the surrounding environment and the ESD control of operators.
Table 5-4 CLM920_RC3 ESD characteristics
Test port
Contact discharge
Air discharge
unit
VBAT power supply
±
4
±
8
KV
Antenna interface
±
4
±
8
KV
Other interface
±
0.5
±
1
KV
5.6 Reliability index
Table 5-5 CLM920_RC3 reliability test
Test items
Test Conditions
Guideline
Test Results
Low
temperature
Temperature:
–
40
º
C
Working mode: normal
IEC60068-
2-1
Visual inspection: normal
Function check: normal