SonTek/YSI Inc
RiverSurveyor System Manual (May 1, 2007)
8
_
Note
: While we are using
SonUtils
, if no valid entry is sent to the system for five minutes,
the ADP may power itself down to conserve energy. If this happens, just send another
Break
to the ADP to wake it up again. Whether or not your ADP goes to sleep after five minutes
depends on the system configuration. Typically, a Standard or Mini ADP system will go to
sleep after five minutes; a RiverCat will not go to sleep.
_
Let’s record all our commands and the results to a log file in case we need to review any set-
tings or problems. Click
File|Open Log File
(or press
Ctrl+L
). Enter a file name and location
when prompted.
_
Click each of the following four controls to get various listings that show how your system
is configured.
Show Configuration
– Lists the ADP hardware configuration. Example:
>show conf
HARDWARE CONFIGURATION PARAMETERS
---------------------------------
Sensor serial # -------------- M001
Sensor type -- (kHz) --------- 500
Number of beams -------------- 3
Beam Geometry ---------------- 3_BEAMS
Slant angle -- (deg) --------- 25.0
Orientation ------------------ DOWN
Compass/Tilt sensor ---------- YES
Recorder sensor ---------- YES
Temperature sensor ---------- YES
Pressure sensor ---------- NO
PressOffset - (dbar) --------- 0.000000
PressScale -- (dbar/count) --- 1.000000
PressScale_2 (pdbar/count^2) - 0
External sensors ------------- NO
External Pressure Sensor ----- NO
Microcat CTD ----------------- NO
GPS Option ------------------- YES
Bottom Track Option ---------- YES
Waves Option ----------------- NO
PINGER Option ---------------- NO
Show System
– Lists current system parameters. Example:
>show system
CURRENT SYSTEM PARAMETERS
-------------------------
CPU Ver ----- ADP 8.0
DSP Ver ----- DSP 4.0
Board Rev. -- REV D
Date -------- 2003/12/31
Time -------- 19:52:00
AutoSleep --- YES
OutFormat --- ASCII
OutMode ----- AUTO
Recorder ---- ON
RecMode ----- NORMAL
BottomTrack - YES
GPS --------- YES
SyncMode ---- DISABLE
Show Setup
– Lists current ADP setup parameters. Example:
>show setup
CURRENT ADP SETUP PARAMETERS
Summary of Contents for SonTek RiverSurveyor
Page 2: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 ii ...
Page 4: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 iv ...
Page 14: ......
Page 24: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 12 ...
Page 26: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 14 ...
Page 74: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 62 ...
Page 82: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 70 ...
Page 148: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 136 ...
Page 162: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 150 ...
Page 166: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 154 ...
Page 168: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 156 ...
Page 182: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 170 ...
Page 194: ...SonTek YSI Inc RiverSurveyor System Manual May 1 2007 182 ...