background image

 

 

■EPDT-341a■

 

 

 
 
 
 

PRODUCT MANUAL

 

.

 

Thank  you  very  much  for  choosing  the  Yoshitake’s  product.    To  ensure  the  correct  and  safe  use  of  the 

product, please read this manual before use.    This manual shall be kept with care for future references. 
The symbols used in this manual have the following meanings. 

 

          Warning 

This  symbol  indicates  a  potentially  hazardous  situation  that,  if  not  avoided, 
could result in death or serious injury. 

          Caution 

This symbol indicates a hazardous situation that, if not avoided, may result in 
minor or moderate injury or may result in only property damage. 

 

 

Table of Contents 

 

1. Usage of the Product ·················································· 1 

2. Specifications ···························································· 1 

3. Dimensions and Weights ············································· 2 

4.

 

Operation   ······························································· 2 

5. Maximum Continuous Discharge Capacity ······················ 3 

6. Installation   

6.1 Piping example ···················································· 4 

6.2 Precaution for installation ······································· 6 

7. Operating Procedure 

7.1 Precaution for operating procedure ·························· 7 

8. Maintenance 

8.1 Precaution for maintenance ··································· 7 

8.2 Daily and periodic inspections ································ 8 

8.3 Troubleshooting ··················································· 9 

8.4 Exploded drawing ··············································· 10 

8.5 Disassembly ······················································ 11 

8.6 Reassembly ······················································· 12 

8.7 Parts replacement procedure ································ 13 

Warranty Information 

 

 

 

 

AIR TRAP 

MODEL TSF-8AT  

Summary of Contents for Trap Star TSF-8AT

Page 1: ...hazardous situation that if not avoided may result in minor or moderate injury or may result in only property damage Table of Contents 1 Usage of the Product 1 2 Specifications 1 3 Dimensions and Wei...

Page 2: ...steel Valve valve seat Stainless steel Connection JIS Rc screwed NPT screwed Flow direction Left to Right Standard Suffix R for Right to Left flow For installation posture see No 4 6 2 Precaution for...

Page 3: ...condensate 3 When condensate is discharged the condensate level falls and the float s buoyancy to the float decreases and the valve closes 4 Condensate can be discharged by repeating the operation of...

Page 4: ...ischarge capacity is of working differential pressure of 0 3 MPa 2 The discharge capacity shown in the charts below is the maximum value In designing a system select an air trap with a sufficient safe...

Page 5: ...e Stop Valve Pressure Gauge Stop Valve Air Trap Strainer Stop Valve Stop Valve Vessel Stop Valve Air Trap Strainer Pressure Gauge Stop Valve Stop Valve Stop Valve Stop Valve Stop Valve Stop Valve Drai...

Page 6: ...g valve To discharge condensate from the main pipe be sure to install the product so that condensate can be discharged from the bottom of the main pipe by drip leg End portion of discharge pipe shall...

Page 7: ...wrong directions prevents it from functioning properly 3 Do not apply excessive load torque or vibration to the valve 4 Check installation posture Wrong posture hampers proper operation Allowable til...

Page 8: ...Precaution for operating procedure Warning 1 Before leading fluid make sure that the product is securely connected to piping and that there is no loose Failure to follow this notice may result in scal...

Page 9: ...ther than the dedicated parts manufactured by Yoshitake Do not modify the product Failure to follow this notice may cause damage to the product or may result in scalds or injury due to blow off or mal...

Page 10: ...osition TOP and BOTTOM signs on upside and downside respectively See Caution No 4 6 2 Precaution for installation on Page 6 Continuous blowout 1 Foreign substances stuck on valve or valve seat 1 Disas...

Page 11: ...gle boxes are available as consumable supply Remove the plug on the TOP side and install an equalizing line Cover Gasket Body Screen Float P Assembly Cover Assembly Plug Plug Bolt Float Holder Float P...

Page 12: ...ench 19 mm Procedure 1 Procedure 1 Loosen the bolts fixing the cover with ring wrench width across flat 19 mm and remove the cover and gasket from the body Pull out the screen from the body Procedure...

Page 13: ...2 Attach the screen to the body The screen can be inserted from either end OK WRONG Connect the float holder and float P assembly with the spindle Check that the float P assembly moves smoothly and th...

Page 14: ...re 3 Install the cover gasket to the cover Make the oval shaped holes on the cover and on the cover gasket in the same position Make sure to use a new cover gasket Apply lubricant agent to the cover g...

Page 15: ...product Yoshitake supplies the repair parts for 5 years otherwise individually agreed 3 This warranty does not cover the damage due to any of below 1 Valve seat leakage or malfunction caused by forei...

Reviews: