Yoshitake GLV-16 Product Manual Download Page 1

EPDT-304b 

GLOBE VALVE 

GLV-16

 

 

PRODUCT MANUAL

 

.

 

Thank you very much for choosing the Yoshitake product. To ensure the correct and safe use of the product, 
please read this manual before use. This manual shall be kept with care for future references. 
The symbols used in this manual have the following meanings. 

 

   

Warning 

This  symbol  indicates  a  potentially  hazardous  situation  that,  if  not  avoided,

 

could result in death or serious injury. 

   

Caution 

This  symbol  indicates  a  hazardous  situation  that,  if  not  avoided,  may  result  in 
minor or moderate injury or may result in only property damage. 

 

1.  Specification

 

 

 

Model 

GLV-16 

Nominal size 

15 to 50A 

Application 

Steam, Air, Cold and hot water, Oil, Other non-dangerous fluids 

Max. using pressure 

2.2 MPa*1 

Max. using temperature 

220

*1 

Connection 

Screwed 

*1 The relation between using pressure and using temperature is according to JIS B2051 Pressure - 

temperature rating. 

 

 

Caution

 

Please  confirm  that  the  indications  on  the  product  correspond  with  the  specifications  of  the  ordered 
product model before use. 

* If they are different, please contact us without using the product. 

 

2. Storage and Installation 

 

  Caution 

(1)  Store the product indoors in a dust free, low humidity, dry and ventilated environment. 
(2)  Installation  should  be  conducted  by  suitably  trained  personnel,  wearing  protective  head,  eye,  hand 

and foot protection. 

(3) To install the product, check the direction of the product so that the fluid flowing and the arrow marked 

on the product are in the same direction. 

(4)  Be  careful  that  the  threaded  connection  between  the  mating  pipe  and  the  internal  threaded 

connections of the valves are in line to avoid piping stresses in the valves. 

(5)  During  transportation  or  storage  of  the  product  leakage  may  occur  from  the  gland  nut  due  to 

decreasing of tightening pressure by stress relaxation of the packing. Be sure to retighten the gland 
nut before use. 

(6) When connecting the product and the piping, apply seal agent (such as seal tape) to the screw part 

of the piping. Use seal agent appropriate for temperature, fluid, etc. 

(7) In case that the product is expected to be frozen, be sure to conduct freezing prevention measures 

or water draining treatment (after use). 

 

3. Operation 

 

  Warning 

Before applying fluid, make sure that there is no danger if the fluid flow into the end of the piping. 

*Failure to follow this notice may result in property damage due to fluid leakage.

 

 

 

Caution

 

(1)  When  using  the  product  with  its  valve  fully  open,  turn  the  handle  counterclockwise  by  45  degrees 

from the fully open position to prevent the valve from being stuck.   

(2)  Be  sure  to  open/close  the  valve  by  applying  torque  within  the  limit  specified  in  "the  valve  User's 

Guide"  published  by  the  Japan  Valve  Manufactures  Association.  Do  not  apply  torque  more  than 
specified. 

(3)  Do  not  try  to  turn  the  handle  beyond  its  fully  open/closed  positions.  Otherwise  the  valve  may  be 

damaged.

 

Reviews: