YORKVILLE synergy SA218S Owner'S Manual Download Page 4

1

Synergy SA218S Powered 

Speaker

Thank you for choosing Yorkville’s Synergy 

SA218S subwoofer, the companion subwoofer 

to the SA153. The SA series excels in sound 

reinforcement applications where a line array is 

desired but cannot be easily accommodated. 

Cabinet Features

The SA218S is constructed of high strength multiply 

birch plywood for ultimate durability. The SA218S 

uses two 18-inch long-throw woofers.

Electronic Features

A Yorkville proprietary DSP platform provides processing 

to prevent over-excursion (X-Max), voice coil overheating 

(VC thermal) and clipping. The DSP uses IIR filters for 

crossover and equalization and there is a small delay 

added to time align with the SA153 top box. The X-Max 

limiter and the VC thermal limiter are both frequency sen

-

sitive and calibrated to match the characteristics of the 

driver and cabinet system. The VC-thermal limiter can be 

advanced to limit the power draw in cases where there 

is less than ample power available. The X-Max limiter is 

faster, pretty much instantaneous. The VC-thermal limiter 

is slower reacting, typically operating near the end of a 

bass beat at 120 bpm.

The amplifier is a high headroom Class-D 

design. There is a large capacitor bank so that 

bass transients are less dependent on the qual

-

ity of the power line.

The limiter indicators indicate when the X-max or 

VC thermal limiters are active. Typically, the X-max 

limiter is more active but this is content dependent. The effect of the line power advance can be observed by 

carefully watching these limit lights as the control is changed while operating in limit. The VC-therm indicator 

will come on sooner as the Average Power limiter is advanced. With many types of music, the effect of the VC-

therm limiter will be minimal.

1. Power Switch and Indicator 

The green power LED illuminates when the power switch is turned to the On position and AC voltage is sup-

plied. When the power is removed or the power switched is moved to the off position the green power indicator 

will blink while the power supply is discharging. The processing circuitry will not reboot unless the power supply 

is fully discharged before being turned back on. It is not necessary to reboot however. Turning the power back 

on before the power supply is discharged will simply resume normal operation.

2. PowerCON TRUE AC Loop Thru 

As a standard, the AC inlet on the SA218S accepts locking PowerCON TRUE power cords. There is also an AC 

outlet that can be used to loop power through to other cabinets in your array using a male to female PowerCON 

TRUE looping power cord. Check with your local Yorkville dealer for availability of these accessory cords.

IMPORTANT: DO NOT EXCEED THE CURRENT RATING OF THE POWER and ACCESSORY CORDS. 

PLEASE READ THE SECTION OF THIS MANUAL CALLED CASCADE INSTALLATION 

3. Input Jack 

This female-XLR accepts line level XLR microphone cables. For best noise reduction use balanced sources.

4. Dual Link Outputs

These XLR male connectors can be used with a standard XLR cable to daisy-chain up to 20 SA218S cabinets 

without signal degradation. Simply loop from one cabinet’s Link jack to the next cabinets Input jack. In many 

cases this limit of 20 cabinets can be exceeded, consult Yorkville Sound for more details.

SA218S

LEVEL

LINE

CURRENT

LIMIT

dB

77

AMPS

88

10

10

55

-12

-24

Activity

Pwr

Limit

X-MAX

VC

Therm

Input

Clip

 10A = MAX Output 

  8A = 90% Output   

  7A = 80% Output  

  5A = 60% Output 

ALL CONNECTED IN PARALLEL

00

-2

-6

Off

Off

8

4

6

2

1

INPUT

OUTPUT

Summary of Contents for synergy SA218S

Page 1: ...OWNER S MANUAL MANUEL DE L UTILISATEUR SA218S SA218S...

Page 2: ...nt de la chaleur Les dispositifs marqu s d une symbole d clair sont des parties dangereuses au toucher et que les c blages ext rieurs connect s ces dispositifs de connection ext rieure doivent tre eff...

Page 3: ...ned to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if...

Page 4: ...the Average Power limiter is advanced With many types of music the effect of the VC therm limiter will be minimal 1 Power Switch and Indicator The green power LED illuminates when the power switch is...

Page 5: ...dicator comes on at 5 mVrms or 45 dBV 7 Line Current Limit Control The Line Current Limit control allows the power to be reduced to allow operation on limited power availability Full power transients...

Page 6: ...surveillant attentivement ces voyants de limiteur lorsque la commande est modifi e pendant le fonctionnement en limite Le voyant VC therm s allume plus t t lorsque le limiteur de Puissance Moyenne es...

Page 7: ...doit tre r duit la source jusqu ce que l activit d cr tage cesse La DEL CLIP s allume 12 Vrms 16 volts cr te L entr e s cr te 17 Vrms 24 volts cr te L indicateur d activit s allume 5 mVrms ou 45 dBV 7...

Page 8: ...passif Actif Puissance du programme watts 6000 watts Programme 12000 watts cr te NPA maximum mesur pond r C maintien maximum 130dB Cont 142 dB cr te R ponse en fr quence Hz 3dB 30 Hz 100 Hz Fr quence...

Page 9: ...6...

Page 10: ...uivalent heavy duty cord supplied by the manufacturer 4 The AC supply cord should be routed so that it is unlikely that it will be damaged Protect the power cord from being walked on or pinched If the...

Page 11: ...alent usage intensif fourni par le fabricant 4 Le cordon d alimentation CA doit tre achemin de mani re qu il soit peu probable qu il soit endommag Prot gez le cordon d alimentation pour qu il ne soit...

Page 12: ...C T U R E D B Y Y O R K V I L L E S O U N D block diagram SYNERGY SA218S 00 1v0PR01 Output Input XLR Sub Level 50Hz LP AC Line Current Sense Line Current Limit Microcontroller DSP ADC DAC 2 3 1 2 3 1...

Page 13: ...pr s de Yorkville Sound ou de votre d taillant Si pour une raison quelconque ce produit devient d fectueux durant les deux ann es qui suivent la date d achat initial dix ans pour l b nisterie retourne...

Page 14: ...alls New York 14305 USA Voice 716 297 2920 Fax 716 297 3689 WORLD HEADQUARTERS CANADA Yorkville Sound Limited 550 Granite Court Pickering Ontario L1W 3Y8 CANADA Voice 905 837 8481 Fax 905 839 5776 REA...

Reviews: