background image

E N G L I S H

OWNER’S MANUAL

YDS03U-011bW-05117

DIGITAL SCROLL CENTRAL AIR-CONDITIONER
(INDOOR UNIT)

Please read this installation manual carefully before installing your air conditioner.
Please keep this manual in a safe place for future reference.
This manual many be subject to change without notice for purpose of improvement.

Summary of Contents for YDS03U-011bW-05117

Page 1: ... CENTRAL AIR CONDITIONER INDOOR UNIT Please read this installation manual carefully before installing your air conditioner Please keep this manual in a safe place for future reference This manual many be subject to change without notice for purpose of improvement ...

Page 2: ......

Page 3: ...CONTENTS SAFETY PRECAUTIONS 4 NOTE BEFORE OPERATION 6 CAUTION 8 PART NAMES 9 OPERATION 13 ADJUSTMENT AIR FLOW DIRECTION 15 MAINTENANCE 17 ABNOMAL PHENOMENON 19 ...

Page 4: ...due to the wrong operation 1 Injury means causing harmed burned electrical shocked but not serious for hospitalization 2 Damage of property means disrepair of property material Protection measures INSTALLATION WARNING Please entrust the dealer or the professional person to do the installation Users can t install the units by themselves or the water leakage electrical shock or fire may be caused Pl...

Page 5: ...r fire Creepage protection switch Ensure the installation place Ventilation FORBID Installation bracket Ensure if the drain pipe can drain the water well Incorrect installation will cause water leakage and humidify the furniture Ensure the installation of creepage protection switch The creepage protection switch must be installed Otherwise the electric shock will be caused Never install the air co...

Page 6: ...will cause injury Do not use the fuse whose capacity exceeds the defined value Using the iron wire or brass wire as fuse can cause the fire and malfunction The power must use the specified circuit under the rated voltage TE CH NICA L GU IDE 2 NOTE BEFORE OPERATION Confirm Before Operation Make sure that the ground wire is not broken or fallen off Make sure the air filter is installed Turn on the p...

Page 7: ...vice When the Protection Device is Activated Cooling Operation The air Intake and the air outlet of the outdoor unit are blocked Strong wind outside is blowing into the air outlet of the outdoor unit Heating Operation The air filter is too dirty The air intake and the air outlet of the indoor unit are blocked Fan Runs after the Indoor Unit Stopped To protect the machine one of the indoor units whi...

Page 8: ...n the power switch 12 hours before starting the unit One of the indoor units can not run on the cooling mode while the other indoor units run on the heating mode Please run every indoor unit on the same mode Put the louver horizontally when cooling There will be water condensing on the louvers if setting the louvers down when cooling Cassette type only Place it away from TV or radio Put the TV or ...

Page 9: ...direction or Three direction Air Outlet For the detailed information please consult your local dealer Lock buckle For closing the Air Grille Air Intake Intake air from here Air Filter Filter the dust in the intake air Air Outlet Horizontal Louver Air Filter Filter the dust in the intake air Air Intake Intake air from here ...

Page 10: ...Horizontal Louver Adjust air out direction Lock buckle For closing the Air Grille Air Intake Intake air from here Air Filter Filter the dust in the intake air Air Filter Filter the dust in the intake air Air Intake Intake air from here Grounding Screw In the control box Air Out Louver Adjust air out direction ...

Page 11: ...zontal Louver Adjust air out direction Air Intake Intake air from here Air Filter Filter the dust in the intake air Air Filter Filter the dust in the intake air Air Intake Intake air from here Grounding Screw In the control box Air Outlet Connect the duct Lock Buckle For closing the air intake grille ...

Page 12: ...Type Thin Duct Ceiling Type Air Outlet Outlet room air Air Intake Intake air from here Heat Exchanger Exchange cool air into warm air Air Outlet Outlet room air Heat Exchanger Exchange cool air into warm air Air Intake Intake air from here ...

Page 13: ...r filter regularly The blocked air filter will reduce cooling heating effects Do not overcool or overheat The blocked air filter will reduce cooling heating effects Check regularly Close the door window Do not let the heat cool air leak from the door window Close the door window WARNING FORBID Do not expose you to the cool wind for a long time Over cool is harm to your health Especially for the ha...

Page 14: ...tion When the cooling operation the air flow down will cause condensing dew on the air outlet and louver surface Four Way Cassette Type Heating operation Adjust the louver down When using the panel with auto louver press SWING button the auto louver will swing automatically and the best cooling heating effects will be achieved One Way Cassette Type Adjust the air direction up and down Maximum air ...

Page 15: ...d Less than 40º Adjust left and right Vertical louver Vertical louver NOTE When adjusting air flow left right refer to the following figures to turn the vertical louver to certain angles and the angle isn t too big otherwise the water drop will be caused The following is how to adjust the air flow direction when the air outlet parts sold separately is used with the indoor unit Heating To effective...

Page 16: ...n the louver will swing up and down automatically Manual Swing Adjust the louver to achieve the better cooling heating effects when cooling heating Adjust the Air Flow Direction Up and Down When cooling Adjust the louver horizontally When cooling Adjust the louver downwards vertically Ceiling Floor Type Auto swing Press SWING button the louver will swing up and down automatically Manual Swing Adju...

Page 17: ...eable air filter is an optional fitting 1 Take out the air in grill Four Way Cassette Type Push the grill switches towards the middle simultaneously as indicated in sketch A Then pull down the air in grill Take out the air in grill together with the air filter shown in Sketch B Pull the air in grill down at 45 and lift it up to take out the grill Cautions The control box cables which are originall...

Page 18: ...reezer 2 Check the air outlet and the air inlet of the outdoor unit regularly to ensure that they are not choked by filth or soot 3 The coil and other parts of the outdoor unit should also be checked regularly Please contact with your local dealer IF YOU DO NOT PLAN TO USE THE UNIT FOR A LONG TIME Operate the fan for about half a day to dry the inside of the unit Turn off the unit with the ON OFF ...

Page 19: ...rs when other indoor unit is heating or cooling The sound of the expansion valve when supplied power If the timer reached the set time If no power If the fuse is blown If starting the protection device the operation lamp lights If the timer is on the set time If choosing the cooling and heating simultaneously If the outdoor unit air inlet or outlet is blocked If the doors and windows are open If t...

Page 20: ...or returned to the manufacturer for disposal Under No circumstances should refrigerant be vented to atmosphere Where appropriate drain the refrigerant oil from each system into a suitable container and dispose of according to local laws and regulations governing disposal of oily wastes 3 Packaged unit can generally be removed in one piece after disconnection as above Any fixing down bolts should b...

Reviews: