FLOOR/CEILING
13
YORK MINISPLIT FLOOR/CEILING
Unit size
12
18
24
36
48
60
D (m)
15
15
22
20
24
20
L (m)
18
18
25
25
30
30
H (m)
12
12
20
22
26
26
OUTDOOR UNIT
■
Unit Fixing
1
Measure and mark the hole position.
2
Drill the hole and fix the outdoor unit.
■
Unit Coupling
Connect electric cable to terminal box follow electric diagrame below.
220-240V/1Ph/50Hz
208-230V/1Ph/60Hz
PCC/POC 12-60 Cooling Only Units
Indoor
Unit
Outdoor
Unit
Power Supply
Indoor
Unit
Outdoor
Unit
380-415V/3Ph/50Hz
Power Supply
PCC/POC 12-60 Cooling Units
Cautions
• Never modify the unit by removing any of the safety guards or by bypassing any of the safety interlock swithces.
• Connect the connecting cable correctly and connect the connecting cable to terminal as identified with their respective
marks.
• Do not scratch the conductive core & inner insulator of power supply cables and do not deform or smash on the
surface of cables.
■
Maximum Piping Lengths
Note : Where the difference in elevation between the
indoor unit and the outdoor unit is greater than 5
meters, install an oil trap every 5 meters.
The suction line must have a 2% gradient up to the compressor on horizontal sections.
Where piping lengths are unusually long and include a large number of oil traps, it may be necessary to adjust to
compressor charge.
N
1
2
L
N
1
2
N
1
2
N
1
2
L
1
L
2
L
3
(continued)