background image

YORK Technical Guide Code 035T76009-000

AIR BLOWER

3

2 - INDOOR & OUTDOOR UNITS

2.1 - INDOOR UNITS

Each unit is shipped with the following items:
- an indoor unit ready for connection to the condensing unit,
- a mounting bracket set,
- a technical guide.

2.2 - OUTDOOR UNITS

The units are shipped complete with a charge of R407C refrigerant sufficient for a piping length of 5 meters.

3 - TECHNICAL SPECIFICATIONS

MAL-MAM

18

25

35

45

55

MOL-MOM

18

25

35

45

55

14,700

19,800

28,000

42,000

50,000

4.3

5.8

8.2

12.3

14.7

3,700

4,990

7,056

10,584

12,600

14,700

19,800

28,000

42,000

50,000

4.3

5.8

8.2

12.3

14.7

3,700

4,990

7,056

10,584

12,600

220-240/1/50 or 380-415/3/50

1

1

3

3

3

1.92

2.91

3.53

4.95

5.76

8.89

13.8

7.97

10

12.1

R-407C

1,170

1,380

1,700

2,500

3,000

102

204

330

330

330

305

305

325

350

350

845

897

962

1,102

1,400

532

567

628

640

640

32

51

53

66

88

Wired or Wireless Control with LCD Display

1

1

1

1

1

Rotary

Rotary

Scroll

590

696

900

1,142

1,142

820

850

1,060

1,060

1,060

280

287

345

345

345

62

68

107

127

127

63

69

109

129

129

Flare and Nuts

5/8"

5/8"

5/8"

3/4"

3/4"

3/8"

5/8"

3/8"

3/8"

3/8"

Piping

Fa

n

Indoor Unit

Outdoor Unit

Models

Cooling

Nominal

Capacities

Heating

Power Supply

Power Consumption

Running Current

Refrigerant Type

Air Flow

Input Power

Height

Dimension

Width

Depth

Weight

System Operation Control

Qty

Compressor

Compressor Type

Height

Dimension

Width

Depth

Weight

Cooling

Heating

Type

Suction

Pipe Size

Liquid

Indoor

Unit

Outdoor

Unit

Btu/h

kW

kcal/h

Btu/h

kW

kcal/h

V/Ph/Hz

Ph

kW

A

m

3

/h

W

mm

mm

mm

kg

mm

mm

mm

kg

inch

inch

02_MAL-MAM.p65 

20/4/02, 09:42

3

Summary of Contents for MAL-MAM 18

Page 1: ...MINISPLIT AIR BLOWER 035T76009 000 TECHNICAL GUIDE MODELS MAL MAM 18 55 01_MAL MAMCover p65 19 4 02 11 28 1...

Page 2: ...interconnection cord used must not be lighter than Polychloroprene sheated cord 245 IEC 57 or H05RN F Disconnecting device must have a contact separation of at least 3 mm GENERAL PRECAUTIONS Check th...

Page 3: ...76 8 89 13 8 7 97 10 12 1 R 407C 1 170 1 380 1 700 2 500 3 000 102 204 330 330 330 305 305 325 350 350 845 897 962 1 102 1 400 532 567 628 640 640 32 51 53 66 88 Wired or Wireless Control with LCD Dis...

Page 4: ...MAL 35 MAL 45 MAL 55 A 845 897 962 1 102 1 400 B 532 567 628 640 640 C 305 305 325 350 350 D 240 240 268 280 280 E 160 160 160 220 220 F 102 5 128 5 133 161 309 G 110 112 115 230 230 H 125 155 145 78...

Page 5: ...inimum of clearance is necessary around the units to ensure proper air circulation and easy access for maintenance CLEARANCE REQUIRED FOR INDOOR UNITS C B D A E Unit A B C D E 18 400 200 100 250 600 2...

Page 6: ...0 mm in height must also be provided If possible install a U bend fitted with an inspection cap Where the condensate lines from several units are joined together each individual outlet must be fitted...

Page 7: ...pump and down to 5 pa 3 When pump down is finished wait 15 minutes to detect potential circuit leakage Open service valves on the outdoor unit If piping length exceeds 5 meters add 10 g of refrigerant...

Page 8: ...L W O FILTER 230 1 50 Avialable Ext Static Pa Airflow CMH Hi 180 160 140 120 100 80 60 40 20 0 300 00 500 00 700 00 900 00 1100 00 1300 00 1500 00 Me Lo Avialable Ext Static Pa Airflow CMH FAN PERFORM...

Page 9: ...is used to protect against any damage to the unit caused by fluctuation of voltage If voltage is lower than the lower limit for approximately 10 seconds or longer compressor operation will be tempora...

Page 10: ...st be pressed again to reset the timer function To cancel either the Start or Stop Timer setting press the CANCEL button To check the time that has been entered either for starting or stopping the uni...

Page 11: ...al Operation Normal Operation Normal Operation Normal Operation Normal Operation Normal Operation Protection Protection Protection Protection Protection Reset Call Service Technician Reset Call Servic...

Page 12: ...80 415V 3Ph 50Hz 480V 3Ph 60Hz Power supply 380 415V 3Ph 50Hz 480V 3Ph 60Hz N 1 2 3 N 1 2 3 L1 L2 L3 N 1 2 L N 1 2 Indoor unit Indoor unit Outdoor unit Indoor unit Outdoor unit Indoor unit Unit size P...

Page 13: ...more often if necessary Each season before start up Each season before start up MAINTENANCE OPERATIONS 1 Clean with a vacuum cleaner or tap gently then wash in warm water 40 C with a mild detergent 2...

Page 14: ...ection factor C2 Capacity correction factor for temperature Indoor unit 10 0 98 5 1 00 R C Standard rating conditions Indoor 27 C DB 19 5 C WB Outdoor 35 C DB 24 C WB Operating temperature limits Cool...

Page 15: ...YORK Technical Guide Code 035T76009 000 AIR BLOWER 15 03_MAL MAM p65 20 4 02 09 43 15...

Page 16: ...to a suitable container using a refrigerant reclaim or recovery unit This refrigerant may then be re used if appropriate or returned to the manufacturer for disposal Under No circumstances should refr...

Reviews: