background image

Summary of Contents for F2FP040H06

Page 1: ...ystem will remove heat and humidity from your home and will transfer this heat to the outdoor air During the heating cycle your system will remove heat and humidity from the outdoor air and will transfer this heat to your home This is possible because even 0 F outdoor air contains a great deal of heat Remember that your heat pump doesn t generate much heat it merely transfers it from one place to ...

Page 2: ...ill operate and the indoor fan will circulate cool filtered air When the room temperature is lowered to the setting selected the system will shut off HEATING YOUR HOME If your system includes a heating unit and the comfort control switch is in the HEAT position the system will operate as follows When the indoor temperature drops below the level indi cated by the temperature adjustment setting the ...

Page 3: ... should be clean to assure maximum efficiency and adequate air circulation Drapes furniture or other obstructions blocking your supply and return air grilles will also decrease efficiency An air filter was supplied by your dealer with you new Air Handler A I filter rack compartment was built in on your new Air Handler and may use either a 1 disposable filter or a permanent washable filter media pe...

Page 4: ... proper settings Set thermostat to proper setting 2 Circuit breakers and fuses Reset circuit breakers Replace blown fuses 3 Check outdoor unit for dirty coil Cooling Clean coil see COIL CARE section 2 No Heat or 4 Outdoor unit for snow accumulation Heating Remove loose snow only 3 Cooling 5 Indoor unit for dirty filter Heating Clean or replace see FILTER CARE section 2 6 Emergency heat light statu...

Reviews: