EOKC 09, 12, 18, 24 R

Floor/Ceiling Multisplit Inverter

Installation Instructions

Johnson Controls Manufacturing España, S.L. is participating in the EUROVENT Certification Programme.
Products are as listed in the EUROVENT Directory of Certified Products, in the program AC1, AC2, 
AC3, LCP and FC.
The LCP program covers air condensed water chillers and heat pumps of up to 600 kW

Ref: 

GB

Summary of Contents for Eokc 12

Page 1: ...s Johnson Controls Manufacturing España S L is participating in the EUROVENT Certification Programme Products are as listed in the EUROVENT Directory of Certified Products in the program AC1 AC2 AC3 LCP and FC The LCP program covers air condensed water chillers and heat pumps of up to 600 kW Ref GB ...

Page 2: ...tdoor operating mode to make the operation normal The cooling mode is not clash with the dry mode while the fan mode is not clash with any mode The appliance shall not be installed in the laundry The appliance shall not be used by children without supervisor An all pole disconnection switch having a contact separation of at least 3mm in all poles Missing information regarding electric supply toler...

Page 3: ...ype Indoor Unit 6 1 Space dimension for installation of the unit 6 2 Important notice 6 3 There are 2 styles of installation 6 4 Electrical wiring 9 5 Install the drainage pipe 10 6 Install the connection pipes 11 Constitutes and Names of Every Part of Floor And Ceiling Type Indoor Unit 12 Working Temperature Range 13 Maintenance Method 14 14 2 Cleaning the unit 14 3 At the start of the season 14 ...

Page 4: ...d Do not mangle wire or adopts wires that are not recommend to use otherwise electric shock or fire may happened Please don t operate the unit by wet hand or electric shock may happened Don t insert finger or stick like things into outlet vent otherwise damage may be happened Cut down the main power switch immediately if malfunction such as smell the burning odor etc happen and then contact the sp...

Page 5: ...of Installation Location Such a place where cool air can be distributed throughout the room Such a place where is condensation water is easily drained out Such a place that can handle the weight of indoor unit Such a place which has easy access for maintenance Such a place where is permitting easy connection with the outdoor unit Such a place where is 1m or more away from other electric appliances...

Page 6: ...ny malfunction caused by the unit that is installed by the department that is not special nominated by YORK would not deal with on time by the inconvenience of the business contact b It should be done by professional personnel when the air conditioner unit is moved to other place 3 There are 2 styles of installation Ceiling type Floor type Each type is similar to the other as follows a Determine t...

Page 7: ...n it is outside the arrowed position Refer to Fig 6 Suspension bolt stays inside the cap of indoor unit Never remove the cap e Lift the unit and slide forward unit the dent Refer to Fig 7 f Screw tightly both hanger bracket setting bolts M8 Refer to Fig 5 g Screw tightly both hanger bracket fixing bolts M6 to prevent the movement of the indoor unit Refer to Fig 5 h Adjust the height so that rear s...

Page 8: ...Fig 4 Fig 5 Hanger bracket setting bolt M8 Hanger bracket fixing bolt M6 Hanger bracket Fig 6 Fig 7 Fig 9 Fig 8 When installing the indoor unit you can refer the paper pattern for installation and make sure that the drainage side must be 10mm lower than the other side in order t Unit mm Model A B H C D EOKC 09 R 1220 225 700 1158 280 EOKC 12 R EOKC 18 R EOKC 24 R A B C D H ...

Page 9: ... the bottom of the appliance upward then connect the brown wire to the Terminal board 3 black wire the communication wire to the Terminal board 2 blue wire to the Terminal board N 1 and connect the earthing wire to the screw terminal on the electric box Clamp them with the corresponding wire clamp packed in the chassis e Reassemble the electrical box cover f Recover the surface panel g The tempera...

Page 10: ...of the drainpipe should be equal to or greater than the diameter of the connecting pipe Keep the drain pipe short and incline downwards at a gradient of at least 1 100 to prevent air pockets Refer to Fig 10 Use the attached drain hose and clamp Insert the drain hose completely into the drain socket Tighten the clamp within the range of gray tape until the screw head is less than 4mm from the hose ...

Page 11: ...onnection pipes Connect the connect pipe with the two relative leading pipe tie the nut on tie in of the connect pipe tightly Caution Be careful in bending the connection pipes or you will damage the pipes If the tightening torque is too great in tightening the flare nut leakage will happen The temperature of refrigerant circuit will be high please keep the interconnection away from the copper tub...

Page 12: ...itutes and Names of Every Part of Floor And Ceiling Type Indoor Unit Surface Panel Connecting pipe Air outlet Air inlet Guide louver Air filter purifier in air inlet grille Suitable model EOKC 09 R EOKC 12 R EOKC 18 R EOKC 24 R Note The appearances will be same by the different models of air conditioners ...

Page 13: ...ature Range Working Temperature Range Indoor side state Outdoor side state Dry bulb temp Wet bulb temp Dry bulb temp Wet bulb temp Rated Cooling 27 19 35 24 Max cooling 32 23 48 26 Min cooling 21 15 18 Rated Heating 20 15 7 6 Max heating 27 24 18 Min heating 20 15 15 16 ...

Page 14: ...ecessary 2 Cleaning the unit Clean the air conditioner and the remote control with dry cloth or a vacuum cleaner If damp cloth is used remove moisture by using dry cloth afterward Caution Do not use benzene gasoline thinners or polishing products for cleaning Do not wash with hot water above 40 Some parts of the unit may be deformed 3 At the start of the season Check if there is blockage in inlet ...

Page 15: ...re to diffuse cool air Clean the air filter every week for higher efficiency by professional Close window and door while operating the unit to prevent leakage of cooled air and save energy Draw close curtains or close glass windows when cooling to prevent heat load from sun light which may cause more electricity cost In case of ineffective ventilation open the window to ventilate the room air once...

Page 16: ...it should be done by professional Do not use pieces of wire instead of fuse Do not insert objects into the air inlet or outlet when the air conditioner is running as it may cause damage or personal injury Also pay special attention when children are around Do not locate any obstacle against the air flow direction of indoor and outdoor unit Otherwise it can cause inefficient performance or malfunct...

Page 17: ...d be operated by professional The cooling heating effect of the air conditioner is not good Is the temp set in proper Is the inlet outlet vent of outdoor unit blocked Is the air filter too dirty to cause blockage Are windows and doors closed Is air quantity set to Low speed Is there other heating resource in room Wireless remote controller cannot control Under the circumstance of changed batteries...

Page 18: ...by johnson controls 18 ...

Page 19: ...1000 6 3 EN61000 6 1 EN61800 3 EN ISO 9001 EN ISO 14001 2006 95 CEE 2004 108 CEE 97 23 CEE NORMAS INTERNACIONALES Y ESPECIFICACIONES TÉCNICAS APLICADAS Paseo Espronceda 278 08204 SABADELL TYPE EC STANDARDS APPLIED DECLARATION OF COMPLIANCE ON MACHINERY MANUFACTURER JOHNSON CONTROLS MANUFACTURING ESPAÑA S L ADDRESS We hereby certify that the mentioned equipment has been designed manufactured and te...