background image

036-21320-002 Rev. A (1103)

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

SPLIT-SYSTEM HEAT PUMPS

12 SEER

MODELS:

E*BC-F018 THRU 060
(1.5 THRU 5 TONS, 1 PH)

E*BC-(T,W)036 THRU 060
(3 THRU 5 TONS, 3 PH)

Due to continuous product improvement, specifications 
are subject to change without notice.

Visit us on the web at www.york.com for the most 
up-to-date technical information.

Additional rating information can be found at 
www.ariprimenet.org.

U

N

IT

AR

Y

HE

AT

P

U

M

P

T

E QUI P ME N

R

S E CT

I O

N S

A T I O N

E

RT

I F I

C

C

O

F

D

S T A N D A R

I

AR

2 4

0

M

A

N

U

F

A

C

TU

R

E

R

CE

RT

I F I

E D

C

LY

OM

P

I

NG

T O A R I AS

LISTED

This product was manufactured
in a plant whose quality system
is certified/registered as being
in conformity with ISO 9001.

Certification applies only

when the complete

system is listed

with ARI.

 

TECHNICAL
GUIDE 

TECHNICAL
GUIDE 

DESCRIPTION

The 12 SEER series heat pumps are designed for use with a
variety of UPG evaporator sections to suit any application
need. A full line of matching Add-On Coils are available for use
with upflow, downflow or horizontal furnaces. Matching Air
Handlers are also available for upflow, downflow or horizontal
installation to provide a complete system. Electric heat may be
installed in air handlers. All units are factory charged to assure
easy installation.

WARRANTY

Single Phase Units:
5-year limited parts warranty.
10-year limited compressor warranty.
Three Phase Units:
1-year limited parts warranty.
5-year limited compressor warranty.

FEATURES

DURABLE CONSTRUCTION - 

The outdoor unit is con-

structed of pre-painted steel that offers tough protection
against corrosion and resists fading when exposed to sun-
light. Drain holes are incorporated into the base pan to per-
mit free drainage of moisture.

QUALITY COILS - 

The coil is constructed of copper tube

and aluminum fins.

COIL PROTECTION -

 Coils are protected from damage by

a polymer mesh applied between the coil face, and a PVC
coated steel coil guard.

PROTECTED COMPRESSOR - 

The hermetic compressor

is internally protected against high pressure and tempera-
ture by the simultaneous operation of a high pressure relief
valve and temperature sensors which stop the compressor
if operating temperatures go too high. Both protectors reset
automatically. A discharge line solid core filter drier further
protects the compressor.

TIME TEMPERATURE DEFROST CONTROL 

- Includes a

five-minute anti-short cycle timer to protect the compressor
from short cycling. Field selectable 30, 60, 90 minutes
defrost intervals.

LOW OPERATING SOUND LEVEL - 

The compressor is

mounted on rubber isolators to reduce operating sounds.
The slow moving condenser fan keeps air turbulence and
sound to a low level.

EASY ACCESS - 

Removable panel affords accessibility to

the electrical box.

FULLY CHARGED AND FACTORY WIRED - 

to simplify

installation and reduce labor costs. Only power supply and
control wiring and refrigerant lines must be connected. All
models are sweat connect with reusable service valves.

Factory tested 

- to verify system operation and control

functioning before shipment.

U.L. and C.U.L. 

listed - approved for outdoor application.

Certified in accordance with the Unitary Small Equipment certi-

fication program, which is based on ARI Standard 210/240.

Summary of Contents for EABC-F018S

Page 1: ...DURABLE CONSTRUCTION The outdoor unit is con structed of pre painted steel that offers tough protection against corrosion and resists fading when exposed to sun light Drain holes are incorporated int...

Page 2: ...T060S EABC W036S EABC W048S EABC W060S Unit Supply Voltage 208 230 3 60 460 3 60 Normal Voltage Range 1 187 252 432 504 Minimum Circuit Ampacity 13 7 20 8 24 2 7 2 10 5 11 7 Max Qvercurrent Device Amp...

Page 3: ...4 87 0 96 54 7023 24 G2FD061H24 90 87 10 96 154 G1HA024H14 61 53 02 G1HA024H14T TXV 701 02 0 G1HA036H14 75 G1HA036H14T TXV 702 05 0 G1HA036H17 78 75 03 78 11 G1HA036H17T TXV 702 0 11 G1HA048H21 84 75...

Page 4: ...des refrigerant for the condenser the smallest evaportor and for 15 feet of interconnecting line tubing 2 Verify the orifice size and additional charge required for specific evaportor coil in the syst...

Page 5: ...50 11 90 N1VSD20 8 10 15 20 25 30 24 G2FD061H24 1900 59 5 44 0 12 35 11 05 1 PH 12 SEER HP F2RP FP FV 4 5 EABC F018S F2RP F2FP024 5 8 10 18 650 18 0 13 3 12 00 10 50 EABC F024S F2RP F2FP030 5 8 10 15...

Page 6: ...14 G1FA036S14 1025 28 2 20 4 11 50 10 35 17 21 G1FA036S17 21 1025 27 8 20 6 11 50 10 25 14 G1HA036H14T 1025 27 4 20 7 12 00 12 00 10 45 G1HD036 1025 28 2 22 4 12 00 10 35 G1HD048 1025 29 4 23 3 12 15...

Page 7: ...G2FD061H24 1600 47 0 36 3 12 00 11 00 EABC T W 048S 1400 1800 21 G1FA048 S H 21 1600 45 0 32 5 12 00 10 25 21 24 G1FA060 S H 21 24 1600 45 5 33 0 12 00 10 35 24 G1HA060H24 1600 45 0 32 5 12 00 10 30 2...

Page 8: ...H 21 T 21 1200 34 6 25 8 12 75 11 15 G8V 20UHC G2FD042 S H 21 T 21 1200 34 8 26 2 12 75 11 10 G9V 12DHB G2FD036 S H 17 T 17 1130 33 4 24 7 12 00 10 85 G9V 12UPB G2FD036 S H 17 T 17 1200 33 8 25 1 12...

Page 9: ...4 1 51 13 0 1 58 15 2 1 63 20 4 1 65 G1UA024S14 17 18 8 3 14 1 75 10 4 2 02 1 50 7 0 5 0 1 33 7 7 1 42 13 1 1 59 15 8 1 67 21 8 1 84 G1UA030S14 19 0 3 22 1 73 10 4 2 04 1 49 7 1 4 7 1 33 7 5 1 42 12 8...

Page 10: ...9 34 0 3 70 38 4 3 79 53 5 4 52 G1HD060S 46 5 3 24 4 21 29 6 2 38 3 64 8 0 18 3 3 27 24 0 3 46 33 7 3 71 37 9 3 78 52 1 4 39 G1NA042S24W 48 5 3 36 4 22 30 4 2 50 3 56 8 0 18 3 3 13 24 4 3 35 34 3 3 65...

Page 11: ...03 13 6 2 14 21 6 2 27 25 8 2 34 35 2 2 41 G9V 12DHB G2FD036 S H 17 29 6 3 50 2 48 17 8 2 34 2 23 8 00 9 8 2 11 13 7 2 21 21 5 2 32 25 7 2 42 34 8 2 48 EABC F036S G8V 16UHB G2FD036 S H 17 34 9 3 68 2...

Page 12: ...SOUND RATINGS Rated in accordance with ARI Standard 270 All dim ensions are in inches They are subject to change without notice Certified dimensions will be provided upon request EBBC F060S G8V 20UHC...

Page 13: ...CUIT BREAKER POWER WIRING 24V CONTROL WIRING NEC CLASS 2 JUMPER TERMINALS E AND W TOHEAT ON FIRST STAGE DURING EMERGENCY HEAT 1 2 TERMINAL NOT USED ON ALL THERMOSTATS POWER WIRING 208 230 1 60 230 1 5...

Page 14: ...1 9 16 0 15 5 13 5 KW 1 68 1 64 1 61 1 75 1 71 1 67 1 81 1 76 1 73 105 T C 17 7 15 5 13 5 18 8 16 4 15 2 19 8 17 3 16 9 S C 11 5 10 4 9 6 13 4 12 4 11 0 15 3 14 4 12 4 KW 1 76 1 71 1 69 1 83 1 78 1 75...

Page 15: ...15 2 15 9 17 0 17 0 16 3 17 0 17 6 17 6 16 9 17 6 KW 2 39 2 35 2 31 2 25 2 45 2 41 2 38 2 31 2 50 2 47 2 43 2 38 115 T C 21 3 19 4 17 9 15 9 21 5 19 7 18 2 16 6 21 7 19 9 18 3 16 8 S C 15 1 15 1 14 5...

Page 16: ...18 9 17 7 15 9 21 8 20 2 18 5 23 8 22 5 20 4 KW 2 79 2 75 2 70 2 89 2 84 2 79 3 03 2 98 2 93 115 T C 25 0 21 7 19 5 26 5 23 0 20 5 27 5 24 0 20 9 S C 18 0 16 7 14 8 20 9 19 2 17 5 23 1 21 3 19 2 KW 2...

Page 17: ...C 23 4 21 6 20 1 25 8 23 9 22 2 28 1 26 1 24 2 KW 3 19 3 10 3 04 3 26 3 17 3 11 3 39 3 32 3 25 115 T C 30 4 26 5 24 1 31 4 27 4 24 7 32 4 28 2 25 3 S C 22 6 20 3 19 1 24 9 22 5 21 0 27 3 24 8 22 9 KW...

Page 18: ...3 9 33 8 29 1 KW 3 00 2 90 2 77 2 75 2 80 3 10 3 00 2 92 2 88 2 98 3 20 3 10 3 07 3 01 3 17 95 T C 38 2 33 4 29 1 28 8 29 1 38 7 34 6 31 8 30 6 31 8 39 2 35 8 34 5 32 4 34 5 S C 18 7 23 7 28 2 28 0 23...

Page 19: ...3 85 3 82 3 78 4 02 3 98 3 96 3 92 105 T C 39 4 36 3 33 9 30 6 39 8 36 8 34 3 31 1 40 0 37 0 34 5 31 9 S C 26 4 26 5 25 8 27 2 28 0 28 3 27 1 28 8 29 3 29 3 28 1 30 2 KW 4 07 4 04 4 00 3 96 4 17 4 13...

Page 20: ...6 43 6 40 3 36 1 47 9 43 9 40 5 36 5 S C 30 4 30 4 29 3 30 9 32 9 32 9 31 7 33 3 33 9 33 9 32 7 34 5 KW 4 60 4 48 4 37 4 22 4 74 4 62 4 52 4 38 4 82 4 69 4 59 4 46 115 T C 44 8 40 9 37 5 33 6 45 5 41...

Page 21: ...5 27 5 23 5 38 5 35 5 30 5 46 5 43 5 38 105 T C 57 5 52 4 47 6 58 5 53 6 48 6 59 4 54 7 49 6 S C 38 5 36 2 34 0 41 3 38 8 36 5 44 1 41 3 39 0 KW 5 90 5 85 5 79 5 98 5 93 5 87 6 06 6 01 5 95 115 T C 54...

Page 22: ...48 7 42 2 50 5 KW 4 63 4 55 4 47 4 47 4 84 4 71 4 62 4 57 4 57 4 92 4 79 4 70 4 68 4 66 5 01 95 T C 60 1 53 7 48 7 48 7 48 7 60 9 54 6 49 4 49 4 49 4 61 6 55 4 50 0 50 1 50 0 S C 28 5 36 2 43 5 36 6...

Page 23: ...70 13 1 1 46 2 64 13 9 1 45 2 80 14 6 1 45 2 97 80 11 1 1 62 2 01 12 0 1 66 2 13 12 9 1 69 2 23 17 60 11 2 1 46 2 26 11 6 1 50 2 27 12 0 1 55 2 28 70 9 8 1 46 1 98 10 6 1 50 2 06 11 3 1 55 2 13 80 8...

Page 24: ...2 06 14 4 2 04 2 07 80 11 7 2 01 1 71 12 5 2 04 1 79 13 0 2 09 1 82 10 60 12 5 1 81 2 02 13 3 1 86 2 09 13 6 1 90 2 10 70 10 5 1 85 1 67 11 7 1 90 1 81 12 3 1 94 1 86 80 8 5 1 89 1 31 10 2 1 94 1 54...

Page 25: ...2 74 70 17 3 2 28 2 23 18 0 2 38 2 20 18 6 2 20 2 49 80 15 7 2 36 1 95 16 5 2 41 2 00 17 4 2 28 2 24 10 60 16 0 2 14 2 20 16 7 2 19 2 24 17 5 2 07 2 47 70 14 1 2 18 1 90 15 2 2 23 2 00 16 0 2 11 2 23...

Page 26: ...54 2 63 23 2 2 58 2 64 70 20 0 2 57 2 29 20 6 2 62 2 30 21 1 2 67 2 32 80 17 9 2 65 1 98 18 5 2 70 2 01 19 1 2 76 2 03 10 60 18 8 2 36 2 34 19 4 2 42 2 36 20 0 2 47 2 38 70 16 2 2 42 1 97 17 1 2 47 2...

Page 27: ...32 9 3 03 3 18 33 0 3 05 3 18 33 1 3 06 3 17 40 60 31 3 2 66 3 45 31 0 2 67 3 41 30 7 2 67 3 37 70 30 3 2 76 3 23 30 5 2 78 3 22 30 7 2 81 3 21 80 29 3 2 85 3 01 30 0 2 90 3 03 30 7 2 95 3 05 30 60 2...

Page 28: ...2 97 80 32 2 3 59 2 63 32 1 3 55 2 65 32 0 3 51 2 67 17 60 26 3 2 94 2 62 26 6 2 95 2 64 26 9 2 97 2 66 70 25 1 3 13 2 35 25 2 3 21 2 30 25 8 3 15 2 40 80 23 8 3 36 2 08 24 3 3 37 2 11 24 7 3 37 2 15...

Page 29: ...39 2 70 31 6 3 43 2 71 32 0 3 46 2 71 70 29 7 3 63 2 40 30 0 3 66 2 41 30 3 3 69 2 41 80 28 2 3 87 2 14 28 4 3 90 2 14 28 7 3 92 2 14 10 60 26 3 3 02 2 56 26 9 3 06 2 58 27 5 3 10 2 60 70 24 6 3 28 2...

Page 30: ...79 42 3 4 41 2 81 80 40 9 4 91 2 45 40 2 4 85 2 43 39 5 4 80 2 41 17 60 34 8 3 92 2 61 35 5 3 92 2 66 36 2 3 92 2 71 70 34 2 4 26 2 36 34 8 4 25 2 40 35 3 4 24 2 44 80 33 6 4 68 2 11 34 0 4 66 2 14 3...

Page 31: ...0 4 97 3 48 60 0 4 99 3 56 80 57 6 5 50 3 07 58 5 5 45 3 15 59 3 5 40 3 22 40 60 53 5 4 42 3 55 54 2 4 41 3 61 54 9 4 40 3 66 70 52 1 4 81 3 20 52 7 4 78 3 26 53 4 4 75 3 32 80 50 6 5 21 2 85 51 3 5...

Page 32: ...DOOR COMPONENTS G1UA 1 2 CASED UPFLOW G1HD HORIZONTAL DUCT G2FD MULTI POSITION UPFLOW HORIZONTAL AND DOWNFLOW Available with factory installed horizontal drain pan ADD ON COILS FOR FURNACE APPLICATION...

Reviews: