background image

036-21687-002-A-1105

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

SINGLE PACKAGE GAS/ELECTRIC UNITS

AND SINGLE PACKAGE

AIR CONDITIONERS

DJ 036, 048 & 060

3, 4 & 5  NOMINAL TONS

13.40 to 13.50 SEER

®  

TECHNICAL GUIDE

DESCRIPTION

YORK Sunline Magnum

units are convertible single pack-

age air conditioners with a common cabinet and a common 
roof curb for the 3, 4 and 5 ton sizes. The units were 
designed for light commercial and commercial applications. 
They can easily be installed on a roof curb, slab, roof jack or 
frame.

All units include:

Powder Paint finish that meets ASTM-B-117 1000 hour 
salt spray standards

Permanently lubricated motors

Bottom or side air discharge configuration capability 
(field convertible)

Manufactured under the quality standards of ISO9001

Simplicity

TM

Control Board

Copper tube/aluminum fin coils

Easy access to all components

Rigging holes in base rails for lifting

Fork lift slots on three sides

Single point power connection

Complete factory package - tested, charged and wired

Belt Drive Indoor Blower

CSA agency listing on all units

WARRANTY

Factory Limited Parts Warranty

One-year parts warranty

A Five-year parts warranty on the compressor and
electric heat elements.

Ten-year parts warranty on the gas-fired heat
exchangers.

Summary of Contents for DJ 036

Page 1: ...l units include Powder Paint finish that meets ASTM B 117 1000 hour salt spray standards Permanently lubricated motors Bottom or side air discharge configuration capability field convertible Manufactured under the quality standards of ISO9001 SimplicityTM Control Board Copper tube aluminum fin coils Easy access to all components Rigging holes in base rails for lifting Fork lift slots on three side...

Page 2: ...NLET 18 11 DJ048 INDOOR SOUND POWER LEVELS VERTICAL DUCTED DISCHARGE 18 12 DJ060 INDOOR SOUND POWER LEVELS HORIZONTAL DUCTED INLET 19 13 DJ060 INDOOR SOUND POWER LEVELS HORIZONTAL DUCTED DISCHARGE 19 14 DJ060 INDOOR SOUND POWER LEVELS VERTICAL DUCTED INLET 20 15 DJ060 INDOOR SOUND POWER LEVELS VERTICAL DUCTED DISCHARGE 20 16 DJ036 COOLING CAPACITIES 3 TON 21 17 DJ048 COOLING CAPACITIES 4 TON 22 18...

Page 3: ...HW 2SWLRQV 2SWLRQV LVFRQQHFW 1RQ 3ZU G RQY 2XOWHW 9 2SWLRQV 2SWLRQV 2SWLRQV 2SWLRQV GGLWLRQDO 2SWLRQV 6HH 1H W 3DJH QVWDOODWLRQ 2SWLRQV 1R 2SWLRQV QVWDOOHG 7RQ 6XQOLQH 0DJQXP 0RGHO 1XPEHU 1RPHQFODWXUH HOW ULYH 6 5HDG FRQ 1R 6 RQWUROOHU Z 3OHDWHG LOWHUV 5 HOW ULYH 0RWRUL HG DPSHU 3 HOW ULYH 6LQJOH QSXW FRQR 1 HOW ULYH LUIORZ 3URGXFW HQHUDWLRQ LUVW HQHUDWLRQ 9ROWDJH 1 0 2XWSXW OXPLQL HG 6WHHO 6WDJH ...

Page 4: ...hase Monitor CQ CPC Controller DFS APS Technicoat Evap Cond Coils Coil Guard CR CPC Controller DFS APS Technicoat Evap Cond Coils Phase Monitor Coil Guard CS CPC Controller DFS APS SS Drain Pan CT CPC Controller DFS APS SS Drain Pan Phase Monitor Coil Guard CU CPC Controller DFS APS SS Drain Pan Technicoat Cond Coils CV CPC Controller DFS APS SS Drain Pan Technicoat Evap Coil CW CPC Controller DFS...

Page 5: ... Controller DFS APS SS Drain Pan Phase Monitor Coil Guard HU Honeywell Excel 10 Controller DFS APS SS Drain Pan Technicoat Cond Coils HV Honeywell Excel 10 Controller DFS APS SS Drain Pan Technicoat Evap Coil HW Honeywell Excel 10 Controller DFS APS SS Drain Pan Technicoat Evap and Cond Coils HX Honeywell Excel 10 Controller DFS APS SS Drain Pan Phase Monitor Coil Guard Technicoat Evap and Cond Co...

Page 6: ...y Intelli Comfort Controller LB Simplicity Intelli Comfort Controller Phase Monitor LC Simplicity Intelli Comfort Controller Coil Guard LD Simplicity Intelli Comfort Controller Phase Monitor Coil Guard LE Simplicity Intelli Comfort Controller Technicoat Cond Coil LF Simplicity Intelli Comfort Controller Technicoat Cond Coil Phase Monitor LG Simplicity Intelli Comfort Controller Technicoat Cond Coi...

Page 7: ...SS Drain Pan Dirty Filter Switch Hinged Filter Door Toolless Access Panels BN SS Drain Pan Phase Monitor Coil Guard Dirty Filter Switch Hinged Filter Door Toolless Access Panels BS Bottom Drain Connection Hinged Filter Door Toolless Access Panels DA CPC Controller with Dirty Filter Switch Air Proving Switch Hinged Filter Door Toolless Access Panels DB CPC Controller DFS APS Phase Monitor Hinged Fi...

Page 8: ...DFS APS SS Drain Pan Phase Monitor Coil Guard Technicoat Evap and Cond Coils Hinged Filter Door Toolless Access Panels GA Honeywell Excel 10 Controller with Dirty Filter Switch Air Proving Switch Hinged Filter Door Toolless Access Panels GB Honeywell Excel 10 Controller DFS APS Phase Monitor Hinged Filter Door Toolless Access Panels GC Honeywell Excel 10 Controller DFS APS Coil Guard Hinged Filter...

Page 9: ...l Guard Dirty Filter Switch Hinged Filter Door Toolless Access Panels UH Technicoat Condenser Coil Phase Monitor Coil Guard Dirty Filter Switch Hinged Filter Door Toolless Access Panels UJ Technicoat Evaporator Coil Hinged Filter Door Toolless Access Panels UK Technicoat Evaporator Coil Phase Monitor Hinged Filter Door Toolless Access Panels UL Technicoat Evaporator Coil Coil Guard Hinged Filter D...

Page 10: ...roller Hinged Filter Door Toolless Access Panels XB Intelli Comfort w Mod Link Controller Phase Monitor Hinged Filter Door Toolless Access Panels XC Intelli Comfort w Mod Link Controller Coil Guard Hinged Filter Door Toolless Access Panels XD Intelli Comfort w Mod Link Controller Phase Monitor Coil Guard Hinged Filter Door Toolless Access Panels XE Intelli Comfort w Mod Link Controller Technicoat ...

Page 11: ...onitors the high and low pressure switches the freezestats the gas valve if applicable and the temperature limit switch on gas heat units The unit control board will alarm on ignition failures compressor lockouts and repeated limit switch trips Nuisance Trip Protection To prevent nuisance trouble calls the control board uses a three strikes you re out philosophy The high and low pressure switches ...

Page 12: ...kel chromium heater elements are pro vided with limit and automatic reset capability to prevent operation at excessive temperatures FILTER OPTIONS Standard units are shipped with 1 throw away filters installed 2 pleated filters are offered as a factory installed option CONVENIENCE OUTLET This 110 volt outlet can be powered by the unit with a stepdown transformer or the unit may be ordered with a n...

Page 13: ...wer to the control board if smoke is detected within the air compartment COIL GUARD Customers can purchase a coil guard kit to protect the condenser coil from damage This is not a hail guard kit STAINLESS STEEL HEAT EXCHANGER For applica tions in corrosive environments this option provides a full stainless steel heat exchanger assembly STAINLESS STEEL DRAIN PAN An optional rust proof stainless ste...

Page 14: ...nvert a single enthalpy economizer to dual enthalpy BURGLAR BARS Mount in the supply and return openings to prevent entry into the duct work FLUE EXHAUST EXTENSION KIT In locations with wind or weather conditions which may interfere with proper exhausting of furnace combustion products this kit can be installed to prevent the flue exhaust from entering nearby fresh air intakes CO2 SENSOR Senses CO...

Page 15: ...n high x 8 ft long 0 30m x 0 46m x 2 44m Cooling Operation2 dB ID Blower Only dB Cooling Operation2 dB ID Blower Only dB TABLE 5 DJ036 INDOOR SOUND POWER LEVELS HORIZONTAL DUCTED DISCHARGE UNIT DESCRIPTION MODEL CONFIGURATION Indoor Blower Speed RPM Blower Static Pressure IWG Airflow CFM Blower Motor BHP 63 80 84 80 83 85 87 84 87 125 74 77 74 76 80 82 80 83 250 58 61 58 61 68 68 63 65 500 48 51 4...

Page 16: ...ly dB 0 36 0 33 0 71 0 49 1069 870 1903 917 0 2 0 3 0 2 0 7 632 632 881 883 DJ036 3 Ton Belt Drive Vertical Ducted Inlet TABLE 7 DJ036 INDOOR SOUND POWER LEVELS VERTICAL DUCTED DISCHARGE UNIT DESCRIPTION MODEL CONFIGURATION Indoor Blower Speed RPM Blower Static Pressure IWG Airflow CFM Blower Motor BHP 63 80 83 80 83 83 86 82 85 125 78 79 77 78 80 83 79 82 250 55 60 54 59 63 63 58 62 500 48 51 46 ...

Page 17: ...sh with reverberation room wall 5 Duct end sound reflection correction 11 6 3 1 0 0 0 0 dB at 63 125 250 500 1k 4k 8k Hz TABLE 9 DJ048 INDOOR SOUND POWER LEVELS HORIZONTAL DUCTED DISCHARGE UNIT DESCRIPTION MODEL CONFIGURATION Indoor Blower Speed RPM Blower Static Pressure IWG Airflow CFM Blower Motor BHP 63 77 97 75 95 84 91 82 91 125 72 86 69 85 81 83 78 80 250 60 62 57 59 71 71 66 67 500 53 56 4...

Page 18: ...n high x 8 ft long 0 30m x 0 46m x 2 44m Cooling Operation2 dB ID Blower Only dB Cooling Operation2 dB ID Blower Only dB TABLE 11 DJ048 INDOOR SOUND POWER LEVELS VERTICAL DUCTED DISCHARGE UNIT DESCRIPTION MODEL CONFIGURATION Indoor Blower Speed RPM Blower Static Pressure IWG Airflow CFM Blower Motor BHP 63 78 95 77 93 85 92 82 91 125 73 84 72 82 84 87 78 82 250 56 58 53 56 68 68 60 61 500 51 54 48...

Page 19: ...HQWHU UHT ORZHU 2QO G 7HVW GXFW WHUPLQDWLRQ LV IOXVK ZLWK UHYHUEHUDWLRQ URRP ZDOO XFW HQG VRXQG UHIOHFWLRQ FRUUHFWLRQ G DW N N N TABLE 13 DJ060 INDOOR SOUND POWER LEVELS HORIZONTAL DUCTED DISCHARGE 81 7 6 5 37 21 02 21 85 7 21 QGRRU ORZHU 6SHHG 530 ORZHU 6WDWLF 3UHVVXUH LUIORZ 0 ORZHU 0RWRU 3 RROLQJ 2SHUDWLRQ G ORZHU 2QO G 2FWDYH HQWHU UHT ORZHU 2QO G RROLQJ 2SHUDWLRQ G ORZHU 2QO G RROLQJ 2SHUDWLR...

Page 20: ... RSHUDWLQJ 7HVW XFW LPHQVLRQ LQ ZLGH LQ KLJK IW ORQJ P P P RROLQJ 2SHUDWLRQ G ORZHU 2QO G RROLQJ 2SHUDWLRQ G ORZHU 2QO G TABLE 15 DJ060 INDOOR SOUND POWER LEVELS VERTICAL DUCTED DISCHARGE 81 7 6 5 37 21 02 21 85 7 21 QGRRU ORZHU 6SHHG 530 ORZHU 6WDWLF 3UHVVXUH LUIORZ 0 ORZHU 0RWRU 3 7RQ HOW ULYH 9HUWLFDO XFWHG LVFKDUJH RROLQJ 2SHUDWLRQ G ORZHU 2QO G 2FWDYH HQWHU UHT ORZHU 2QO G RROLQJ 2SHUDWLRQ G ...

Page 21: ... 28 2 9 28 28 27 24 21 18 15 1200 72 41 2 7 26 23 19 16 12 37 2 9 25 21 18 14 11 67 37 2 7 33 30 26 23 19 16 12 33 2 8 31 28 24 21 17 14 10 62 32 2 7 32 32 32 29 25 22 18 29 2 9 29 29 29 25 22 18 15 57 32 2 7 32 32 32 29 25 22 18 29 2 9 29 29 30 26 23 19 16 1350 72 41 2 7 28 24 20 16 12 37 3 0 27 23 19 15 11 67 37 2 7 35 31 27 23 19 15 11 33 2 9 32 29 25 21 17 13 9 62 32 2 7 32 32 32 28 24 20 16 2...

Page 22: ...7 35 31 27 23 19 1600 72 54 3 4 35 30 26 21 16 49 3 7 33 28 24 19 14 67 49 3 4 45 40 35 31 26 21 17 43 3 7 41 37 33 28 24 19 14 62 44 3 3 44 44 44 39 35 30 25 39 3 6 39 39 39 34 30 25 20 57 43 3 3 43 43 43 39 34 29 25 39 3 6 39 39 39 34 29 25 20 1800 72 53 3 4 38 33 27 22 17 49 3 7 36 31 25 20 15 67 48 3 4 46 43 38 32 27 22 16 43 3 7 42 39 35 30 24 19 14 62 44 3 3 44 44 44 38 33 28 22 39 3 6 39 39...

Page 23: ...9 34 29 24 2000 72 64 4 4 44 38 32 26 21 59 5 0 41 35 29 23 17 67 59 4 4 55 49 43 37 31 26 20 53 4 9 51 46 41 35 29 23 17 62 53 4 3 53 53 53 47 41 35 29 48 4 9 48 48 48 42 36 31 25 57 52 4 4 52 52 52 46 41 35 29 48 4 9 48 48 48 43 37 31 25 2250 72 65 4 5 47 41 34 27 21 60 5 0 44 37 30 24 17 67 59 4 4 57 52 46 39 32 26 19 54 4 9 53 49 43 36 29 23 16 62 54 4 3 54 54 54 47 40 34 27 49 4 9 49 49 49 42...

Page 24: ...5 739 0 79 911 773 0 83 962 806 0 86 1008 838 0 90 1052 871 0 93 2000 887 819 0 88 943 853 0 92 994 886 0 95 1040 918 0 98 1084 951 1 02 AIR FLOW CFM AVAILABLE EXTERNAL STATIC PRESSURE IWG1 0 7 0 8 0 9 1 0 1 1 RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP 800 829 457 0 49 872 495 0 53 916 538 0 58 964 586 0 63 1017 642 0 69 900 839 485 0 52 882 524 0 56 927 566 0 61 975 615...

Page 25: ...9 1051 864 0 93 1900 899 776 0 83 953 818 0 88 1001 860 0 92 1045 901 0 97 1087 939 1 01 2000 936 857 0 92 990 899 0 96 1038 941 1 01 1082 981 1 05 AIR FLOW CFM AVAILABLE EXTERNAL STATIC PRESSURE IWG1 0 7 0 8 0 9 1 0 1 1 RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP 800 831 456 0 49 871 486 0 52 914 509 0 55 961 525 0 56 1012 532 0 57 900 846 477 0 51 886 507 0 54 929 530 0...

Page 26: ...23 1167 1182 1 27 2200 996 1059 1 14 1036 1104 1 18 1077 1150 1 23 1119 1194 1 28 1162 1234 1 32 2300 1034 1151 1 24 1075 1197 1 28 1116 1243 1 33 1158 1286 1 38 2400 1075 1250 1 34 1115 1296 1 39 1156 1341 1 44 2500 1118 1354 1 45 1158 1400 1 50 AIR FLOW CFM AVAILABLE EXTERNAL STATIC PRESSURE IWG1 0 8 0 9 1 0 1 1 1 2 1 3 RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WA...

Page 27: ... 1097 1 18 1143 1139 1 22 1189 1180 1 27 2200 1017 1063 1 14 1056 1098 1 18 1098 1138 1 22 1141 1180 1 27 1186 1223 1 31 2300 1063 1151 1 23 1102 1186 1 27 1144 1226 1 31 1187 1268 1 36 2400 1111 1243 1 33 1151 1278 1 37 1192 1318 1 41 2500 1163 1340 1 44 1202 1376 1 48 AIR FLOW CFM AVAILABLE EXTERNAL STATIC PRESSURE IWG1 0 8 0 9 1 0 1 1 1 2 1 3 RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS ...

Page 28: ... 1082 1107 1 19 1125 1147 1 23 1167 1182 1 27 2200 996 1059 1 14 1036 1104 1 18 1077 1150 1 23 1119 1194 1 28 1162 1234 1 32 2300 1034 1151 1 24 1075 1197 1 28 1116 1243 1 33 1158 1286 1 38 2400 1075 1250 1 34 1115 1296 1 39 1156 1341 1 44 2500 1118 1354 1 45 1158 1400 1 50 AIR FLOW CFM AVAILABLE EXTERNAL STATIC PRESSURE IWG1 0 8 0 9 1 0 1 1 1 2 1 3 RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WA...

Page 29: ...075 1 15 1165 1122 1 20 1204 1167 1 25 2200 1046 1030 1 11 1084 1075 1 15 1123 1121 1 20 1162 1168 1 25 1200 1215 1 30 2300 1082 1128 1 21 1121 1172 1 26 1160 1219 1 31 1198 1266 1 36 2400 1120 1231 1 32 1159 1276 1 37 1198 1322 1 42 2500 1159 1340 1 44 1198 1384 1 48 AIR FLOW CFM AVAILABLE EXTERNAL STATIC PRESSURE IWG1 0 8 0 9 1 0 1 1 1 2 1 3 RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BH...

Page 30: ... 5 8 AK56 5 4 5 2 1 A36 37 3 1 1 All motors have solid bases and are inherently protected These motors can be selected to operate into their service factor because they are located in the moving air upstream of any heating device TABLE 26 STATIC RESISTANCES DESCRIPTION RESISTANCE IWG CFM 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 ECONOMIZER1 3 0 07 0 08 0 09 0 11 0 13 0 15 0 17 0 20 0 ...

Page 31: ...one 10 3 15 2CE045107462 6 8 8 2 13 5 15 2CE045110462 10 1 12 1 18 4 20 2CE045115462 13 6 16 4 23 7 25 2CE045120462 19 5 23 5 32 6 35 575 3 60 3 2 26 0 1 3 2 0 0 0 None 7 0 15 2CE04511058 10 6 10 2 15 2 20 2CE04511558 15 9 15 3 21 6 25 2CE04512058 21 2 20 4 28 0 30 DJ048 208 1 60 15 4 86 0 2 3 7 6 0 0 None 29 1 35 2CE04510506 4 0 19 2 33 5 40 2CE04510706 5 6 26 9 43 2 45 2CE04511006 8 0 38 5 57 6 ...

Page 32: ... 35 2CE04511025 8 0 22 2 34 3 45 2CE04511525 11 9 33 0 47 8 50 2CE04512025 15 9 44 1 61 7 70 2CE04513025 22 2 61 6 83 5 90 230 3 60 17 3 123 0 2 3 5 2 0 0 None 29 1 35 2CE045105252 5 3 12 7 29 1 35 2CE045107252 7 5 18 0 29 1 35 2CE04511025 10 6 25 5 38 4 45 2CE04511525 15 9 38 2 54 3 60 2CE04512025 21 2 51 0 70 2 80 2CE04513025 29 6 71 2 95 5 100 460 3 60 8 4 70 0 1 3 2 6 0 0 None 14 4 20 2CE04510...

Page 33: ...ne 15 3 20 2CE045107462 6 8 8 2 19 7 20 2CE045110462 10 1 12 1 24 7 25 2CE045115462 13 6 16 4 29 9 30 2CE045120462 19 5 23 5 38 8 40 575 3 60 3 2 26 0 1 3 2 0 4 0 None 11 2 15 2CE04511058 10 6 10 2 20 2 25 2CE04511558 15 9 15 3 26 6 30 2CE04512058 21 2 20 4 33 0 35 DJ048 208 1 60 15 4 86 0 2 3 7 6 10 0 None 39 1 50 2CE04510506 4 0 19 2 46 0 50 2CE04510706 5 6 26 9 55 7 60 2CE04511006 8 0 38 5 70 1...

Page 34: ...1 50 2CE04511025 8 0 22 2 46 8 50 2CE04511525 11 9 33 0 60 3 70 2CE04512025 15 9 44 1 74 2 80 2CE04513025 22 2 61 6 96 0 100 230 3 60 17 3 123 0 2 3 5 2 10 0 None 39 1 50 2CE045105252 5 3 12 7 39 1 50 2CE045107252 7 5 18 0 41 6 50 2CE04511025 10 6 25 5 50 9 60 2CE04511525 15 9 38 2 66 8 70 2CE04512025 21 2 51 0 82 7 90 2CE04513025 29 6 71 2 108 0 110 460 3 60 8 4 70 0 1 3 2 6 5 0 None 19 4 25 2CE0...

Page 35: ...ns Per Inch 18 18 18 Face Area Sq Ft 17 1 17 1 17 1 COMPRESSOR Qty Per Unit Quantity 1 1 1 Type Recip Recip Scroll AIR FILTERS Quantity Per Unit 15 X 20 X 1 or 2 2 2 2 Quantity Per Unit 14 X 25 X 1 or 2 1 1 1 Total Face Area sq ft 6 3 6 3 6 3 CHARGE Refrigerant 22 lbs oz 9 4 9 8 11 0 TABLE 31 ELECTRIC HEAT CORRECTION FACTORS NOMINAL VOLTAGE VOLTAGE kW CAP MULTI PLIER 208 208 1 00 240 230 0 92 480 ...

Page 36: ...G LED 1 LED 2 COM A1 A2 T T B R Y1 Y2 G C X OCC W2 W1 THERMOSTAT1 TERMINALS UNIT TERMINAL STRIP TB1 24 VOLT TRANSFORMER TO REMOTE SENSOR 2TH040702224 IF USED NOT USED ADD JUMPER ADD JUMPER 4 4 3 2 1 ELECTRONIC PROGRAMMABLE THERMOSTAT 2ET04700224 INCLUDES SUBBASE 2 SECOND STAGE COOLING IS NOT REQUIRED ON UNITS LESS ECONOMIZER 3 SECOND STAGE HEATING IS ONLY REQUIRED ON UNITS WITH A TWO STAGE ELECTRI...

Page 37: ...036 21687 002 A 1105 Unitary Products Group 37 FIGURE 3 UNIT DIMENSIONS 3 5 TON COOLING ONLY ELECTRIC HEAT FRONT VIEW FIGURE 4 UNIT DIMENSIONS 3 5 TON COOLING GAS HEAT FRONT VIEW ...

Page 38: ...036 21687 002 A 1105 38 Unitary Products Group FIGURE 5 UNIT WITH ECONOMIZER RAINHOOD DETAIL A FIGURE 6 UNIT WITH FIXED OUTDOOR AIR MOTORIZED DAMPER RAINHOOD DETAIL B ...

Page 39: ...artment FIELD SUPPLIED DISCONNECT SWITCH LOCATION BLOWER MOTOR ACCESS FILTER ACCESS DOT PLUGS 1 Opening in the bottom to the unit can be located by the side in the insulation 2 Do not remove the 2 knockout ring TABLE 34 MINIMUM CLEARANCES LOCATION CLEARANCE Front 24 Cooling Electric Heat 32 Gas Heat Rear 12 Less Economizer 36 With Economizer or Fixed Air Motorized Damper Left Side Filter Access 24...

Page 40: ...036 21687 002 A 1105 40 Unitary Products Group FIGURE 9 TYPICAL APPLICATIONS ...

Page 41: ... 89 85 82 102 106 110 DJ036N04 615 141 133 166 175 95 91 88 110 114 118 DJ036D06 625 143 135 168 178 96 93 89 111 115 120 DJ036N08 635 145 138 171 181 98 94 91 113 117 122 DJ036D10 645 148 140 174 184 99 96 92 115 119 124 DJ048 Cooling Electric 585 134 127 158 167 90 87 84 104 108 112 DJ048 D N 06 635 145 138 171 181 98 94 91 113 117 122 DJ048 D N 10 655 150 142 177 187 101 97 94 117 121 125 DJ060...

Page 42: ...N BASIC UNIT DJ Cooling Only 575 585 590 DJ Gas Electric N04 615 N06 635 N08 635 650 N10 655 660 D06 625 635 640 D10 645 655 660 OPTIONS Economizer 50 Motorized Damper 26 Electric Heater 5 7 kW 18 10 15 kW 23 20 30 kW 28 ACCY Roof Curb 92 Barometric Relief Fixed Air Damper 10 FIGURE 11 ROOF CURB DIMENSIONS ...

Page 43: ...its the cooling performance shall be rated in accordance with DOE and ARI test proce dures Units shall be CSA listed classified to ANSI Z21 47 UL 1995 CSA No 236 standards UNIT CABINET Unit cabinet shall be constructed of G90 galvanized steel with exterior surfaces coated with a non chalking powdered paint finish certified at 1000 hours salt spray test per ASTMB117 standards Indoor blower section ...

Page 44: ...ition and redun dant main gas valve Venter wheel shall be constructed of stainless steel for corrosion resistance The heat exchanger shall be of the tubular type constructed of T1 40 aluminized steel for corrosion resistance and allowing minimum mixed air entering temperature of 25 F Burners shall be of the inshot type constructed of aluminum coated steel and con tain air mixture adjustments All g...

Page 45: ...wo pre selected positions regardless of the outdoor air enthalpy Dampers return to the fully closed position when the indoor fan motor is de energized Dampers shall fully close on power loss OTHER PRE ENGINEERED ACCESSORIES AVAILABLE ROOF CURB 14 and 8 high full perimeter curb with wood nailer shipped knocked down BAROMETRIC RELIEF DAMPER Contains a rain hood air inlet screen exhaust damper and mo...

Page 46: ...036 21687 002 A 1105 46 Unitary Products Group ...

Page 47: ...036 21687 002 A 1105 Unitary Products Group 47 ...

Page 48: ...to change without notice Printed in U S A 036 21687 002 A 1105 Copyright 2005 by Unitary Products Group All rights reserved Supersedes 036 21687 001 A 0605 Unitary 5005 Norman Products York OK Group Drive 73069 ...

Reviews: