Summary of Contents for ARTTP001S

Page 1: ...1 THERMOSTATS YORK...

Page 2: ...settings for ARTTP002S SHP 2 5 3 Wiring 5 3 1 Thermostat ARTTP001S SMS 1 terminals 5 3 2 Thermostat ARTTP002S SHP 2 terminals 5 3 3 Connections between thermostat and equipment ARTTP001S SMS 1 6 3 4...

Page 3: ...e thermostat has been installed and powered for at least one hour Description Values Rated voltage 20 30 Vac or DC 24V nominal Rated A C current 0 05 Amps to 0 75 Amps continuous per output with surge...

Page 4: ...mostat cover lock If desired insert the plastic lock piece into the bottom of the mounted base The ends of the lock piece should fit snugly under the lock pins extending from the bottom of the mounted...

Page 5: ...cription 2 events include day and night 4 events include morning day evening and night Smart fan on will run fan continuously on occupied mode but cycle the fan in unoc cupied mode with a call for hea...

Page 6: ...VAC common O Energises 4 way valve in cooling mode B LED1 LED2 X Refrigerant circuit fault RS2 Remote Sensor option RS1 RS V No Contacts changeover in occupied mode COM NC Thermostat Unit Description...

Page 7: ...rgency heat mode Normally displays the current time Displays programming times in pro gram mode Heat icon two flickering lines when heat is on Cool icon Flickers when the cooling is on Keypad Locked i...

Page 8: ...the same fashion The setpoints that you have selected to represent your events will be consistent for all 7 days of the week If you change a setpoint in any of the events it will change the correspon...

Page 9: ...isplayed until the mode is changed The OFF mode prevents the systems from being energized however all programmed schedules will be remembered AUTO CHANGE OVER MODE These thermostats can be used to aut...

Page 10: ...utes interval only ie 8 10 8 20 8 30 etc USING THE COPY FUNCTION The copy function has been designed into the PROGRAM button For example with MONDAY programmed for DAY and NIGHT the final function wil...

Page 11: ...bove which the auxiliary heat is locked out If another key is pressed the thermostat will return to normal operation in 15 seconds Press the outdoor button while showing the HibP and the ther mostat w...

Page 12: ...t sensor using the single sensor instructions 2 CAUTION Make sure that there is no power to the sen sors by removing the thermostat from the subbase 3 Connect wires to each additional sensor in the fo...

Page 13: ...300ft 90m Max number of indoor sensors in daisy chain 6 Max number of duct sensors in daisy chain 1 Max number of outdoor sensors in daisy chain 1 SINGLE SENSOR MULTIPLE SENSOR TEMPERATURE AVERAGING...

Page 14: ...ter minals labelled RS2 RS1 and RS V Make sure that each terminal on the sensor is wired to the terminal with the same name on the thermostat 14 Mount the thermostat on the subbase and check to be sur...

Page 15: ...S Mounted indoors Outdoor probe For proper temperature sensing mount probe in the shade ALSRS001S ALSOS001S Outdoor probe SPECIFICATIONS Max number of outdoor sensors in daisy chain 1 Accuracy 2 C fro...

Page 16: ...E UG R0002 Manufacturer reserves the right to change specifications without prior notice YORK Europe YORK INTERNATIONAL...