Battery Low Indication:

Whenever the battery is low, there will appear a battery low indication

symbol on the screen (bottom right). This indicates that the battery is

low and should be replaced soon. The unit will continue to perform in

battery low condition within the specified accuracy and turns off when

the battery reaches the limit.

Holding/Freezing the Reading:

While measuring, if the reading needs to be frozen for any observation,

press the power button during measurement. A text “HOLD” will be 

displayed on the screen.

9. Battery Replacement

A 550mAh battery will last continuously for more than 20 hours for a

Surveymaster in operation. A Battery Low indication on the screen 

indicates that the battery needs to be changed in a short time.

Remove the screw assembled to fix the battery lid on the back side of

the unit.

Slide the battery lid downwards applying a little pressure with the thumb

to open the battery compartment.

Remove the battery and replace. Care must be taken to ensure that the

polarity is correct. Place the battery in side the compartment.

10. Technical Specifications

Operating Conditions:

Operating temperature range: 0°C to 50°C

Humidity: 0 to 90%RH, non-condensing

Measurement Specifications:

Moisture measurement:

For integrated and remote pin probes:

Strong and reliable integrated pins with a cap to protect

Pin measurement range (%mc in wood/%WME) - 

7.9 to 99% (readings over 30% are relative)

Non-invasive moisture measurement:

Measurement depth - up to 19mm (¾”) deep,

70 to 999, no effect on reading by surface moisture.

11. Physical Specifications

Power:

9V Alkaline 550mAh, battery low indication on LCD

Size:

19 x 6.5 x 5cm (7.5 x 2.5 x 2”)

Weight (without battery):

240G

Max. needle depth:

For WME pins: 10mm (0.4”)

Buzzer:

Audible buzzer for key tone and measurement indication, user

configurable

Regulatory compliance:

CE, RoHS, ETL