2. Press the 

p

or 

q

button to select ‘Frame Rate’ and then press the ‘OK’ button.

3. Press the 

p

or 

q

button to toggle between different frame rates. Once you have 

highlighted your desired selection, press the ‘OK’ button to confirm and exit.

Time Stamp Setting

1. In the setting mode, press the 

p

or 

q

button to select ‘RECORDER SETTING’ 

and then press ‘OK’ button.

2. Press the 

p

or 

q

button to select ‘Time Stamp’ and then press the ‘OK’ button.

3. Press the 

p

or 

q

button to toggle between on and off. Once your desired selection 

is made, press the ‘OK’ button to confirm and exit.

Recording Type

1. In the setting mode, press the 

p

or 

q

button to select ‘RECORDER SETTING’ 

and then press ‘OK’ button.

2. Press the 

p

or 

q

button to select ‘Recording Type’ and then press the ‘OK’ button.

3. Press the 

p

or 

q

button to toggle between ‘still’ and ‘video’. Once your desired 

selection is made, press the ‘OK’ button to confirm and exit.

Event Playback

1. In the setting mode, press the 

p

or 

q

button to select ‘EVENT PLAYBACK’ and 

then press ‘OK’ button.

2. Refer to the user manual instructions on Playback of Video/Picture, Deleting 

Video/Picture and Deleting Folder for guidance.

TROUBLESHOOTING

SPECIFICATIONS

Actual transmission range of wireless monitoring may vary according to the weather,

location, interference or building construction.

All specifications are subject to minor change without notice.

FCC INFORMATION

This device complies with part 15 of the FCC Rules. Operation is subject to the 

following two conditions:

(1) This device may not cause harmful interference.

(2) This device must accept any interference received, including interference that may 

cause undesired operation. Changes or modifications not expressly approved by 

the party responsible for compliance could void the user’s authority to operate the 

equipment.

The graphics included in this user manual are subject to minor change without notice.

c

a

m

e

r

a

Imaging Sensor

CMOS

Total Pixels

640 x 480 (PAL)

640 x 480 (NTSC)

Horizontal Viewing Angle

36°

Transmission Frequency

2468MHz

Minimum Illumination

0 Lux

Modulation Type

FM

Bandwidth

18MHz

Power Supply

4x AA batteries

Unobstructed Effective Range

10m (max)

Waterproof Capacity

IP67 (for lens/tube only)

Tube Diameter

9mm

Dimensions (WxDxH)

186 x 145 x 41mm (excluding flexible tube)

Approx. Weight

408g

m

o

n

i

t

o

r

LCD Screen Type

3.5” TFT-LCD

Effective Pixels

960 x 240

Video System

PAL/NTSC

Transmission Frequency

2414MHz, 2432MHz, 2450MHz, 2468MHz

Exterior Supply Voltage

5VDC

Consumption Current (Max.)

500mA

Charging Time

3 hours

Working Time

2 hours

Picture/Video Pixels

640 x 480

Video Size

20M byte/minute

Frame Rate

30 frame/second

Video Output Level

0.9-1.3VP-P@75ohm

Receiving Sensitivity

<-85dBm

Dimensions (WxDxH)

100 x 70 x 25mm

Approx. Weight

140g

Operating Temperature

-10°C to +40°C / +14°F to +104°F

Operating Humidity (Max.)

15 to 85%RH

Problem

Possible Cause

Likely Solutions

Tool will not start 1. Monitor not charged

2. Batteries need charging

1. Charge monitor

2. Replace batteries in control

handle

Monitor will not

charge

1. Adaptor cable not attached

properly

2. Adaptor not connected to 

power

1. Make sure adaptor cable is

connected between monitor

and adaptor

2. Make sure adaptor is

securely plugged into wall 

socket

Image too dark

or light

1. LEDs near camera need

adjustment

2. Monitor display needs

adjustment

1. Use dial on control handle to

adjust brightness of LEDs

2. Use contrast and brightness

buttons on monitor to adjust

image

Follow all safety precautions whenever diagnosing or servicing the tool.

Disconnect power supply before service.

Prospect House, George Cayley Drive, Clifton Moor, York, England YO30 4XE

Tel: +44 (0) 1904 692723    Fax: +44 (0) 1904 690385 

E-Mail: [email protected]     www.yorksurvey.co.uk

York Survey Supply Centre

Follow us!

@York_Survey
@York_Survey

Reviews: