background image

This Roof Curb is NRCA approved and is constructed of 14 gauge galvanized steel with a full perimeter 2" X 4" 

wood nailer strip. The curb is shipped with the following parts.

026-36345-002 14" HIGH

026-36345-102 24" HIGH

A

1

Side Panel Right, 78 1/2 x 14

A

1

Side Panel Right, 78 1/2 x 24

B

1

Side Panel Left, 78 1/2 x 14

B

1

Side Panel Left, 78 1/2 x 24

C

1

Side Panel Right, 78 1/2 x 14

C

1

Side Panel Right, 78 1/2 x 24

D

1

Side Panel Left, 78 1/2 x 14

D

1

Side Panel Left, 78 1/2 x 24

E

8

Side Panels, 71.75 x 14

E

8

Side Panels, 71.75 x 24

F

3

End Panels, 83 x 14

F

3

End Panels, 83 x 24

G

3

Brace Panels, 83 x 14

G

3

Brace Panels, 83 x 24

H

1

End Panel, 83 x 11

H

1

End Panel, 83 x 21

J

1

Supply Panel, 43 x 14

J

1

Supply Panel, 43 x 24

K

4

Support Rails, 83 x 3

K

4

Support Rails, 83 x 3

L

5

Condenser Panels

L

5

Condenser Panels

M

10 Splice Channels

M

10 Splice Channels

N

4

Condenser Panel Flashings

N

4

Condenser Panel Flashings

P

1

Hardware Package

P

1

Hardware Package

(100) .375-16 x 1.00 Hex Bolt w/ Nuts

(168) .375-16 x 1.00 Hex Bolt w/ Nuts

(100) .375 Helical Lock washers

(168) .375 Helical Lock washers

(100) .375 Flat Washers

(168) .375 Flat Washers

(157) 25-14 x .75 Screw Tapping

(157) 25-14 x .75 Screw Tapping

(Washer Head Seal Tight)

(Washer Head Seal Tight)

(126 Ft) 3/4 x 1 1/4 Foam Gasket

(126 Ft) 3/4 x 1 1/4 Foam Gasket

(100 Ft) 3/4 x 1/8 Tacky Tape

(100 Ft) 3/4 x 1/8 Tacky Tape

PACKAGED ROOFTOP UNITS

INSTALLATION INSTRUCTIONS

NEW RELEASE

Form YRK2-N1 (319)

ROOF CURB

70–85 TON FULL PERIMETER

MODEL # 026-36345-002 / 026-36345-102

Summary of Contents for 026-36345-002

Page 1: ...H 1 End Panel 83 x 21 J 1 Supply Panel 43 x 14 J 1 Supply Panel 43 x 24 K 4 Support Rails 83 x 3 K 4 Support Rails 83 x 3 L 5 Condenser Panels L 5 Condenser Panels M 10 Splice Channels M 10 Splice Ch...

Page 2: ...nated holes on Side Panels E Make sure the corners are flush and square as shown on Figure 2 Place the curb in the proper location Make sure the curb section is IN SQUARE 5 Layout the curb pieces as s...

Page 3: ...f End Panel H through the designated holes on Side Panel Right A and Side Panel Left B Make sure the cor ners are flush and square as shown on Figure 5 Place the curb in the proper location Make sure...

Page 4: ...TACKY TAPE L 5 TACKY TAPE TACKY TAPE TACKY TAPE K K K K H 12 1 8 11 5 8 10 1 2 11 10 Make sure Support Rails K are located properly so condensation can run off con denser panels Refer to Figure 6 13 A...

Page 5: ...PE BY HOLES L 5 TYP 1 1 2 FLANGE PLACE TAPE ALONG ALL CONDENSER PANEL BETWEEN 1 FLANGE AND CURB SIDE 2 CURB EDGE 4 2 1 3 5 Figure 9 LD08557 Refer to Figure 10 N N 2 1 2 1 2 15 Install the sloped Conde...

Page 6: ...OOD NAILER COUNTER FLASH ING FIELD SUP PLIED ROOF ING FELT FIELD SUP PLIED FLANGE SIDE ROOF INSTRUCTIONS RIGIDINSULATION FIELD SUP PLIED CANT STRIP FIELD SUP PLIED FOAM GASKET FLAT SIDE Figure 11 LD08...

Page 7: ...5 292 449 43 67 48 2 Flange Side Flat Side 2 Flange Width on Entire Curb Figure 12 LD08560 All dimensions are critical to ensure prop er fit of the unit to the curb All dimen sions are from the Flat S...

Page 8: ...S A REGISTERED TRADEMARK OF JOHNSON CONTROLS 2019 Johnson Controls 100 JCI Way York Pennsylvania USA 17406 8469 www york com Subject to change without notice Form YRK2 N1 319 New Release All rights re...

Reviews: