Gas/Water Valve
User Guide
YS4907
-
UC
Page 1: ...Gas Water Valve User Guide YS4907 UC...
Page 2: ...ater Valve 4 YoLink Control 15 Maintaining the Gas Water Valve 18 Using YoLink App with Gas Water Valve 10 Speci cations 20 Installation 8 Product Requirements 3 Introduction 2 Features 3 Troubleshoot...
Page 3: ...1 What s Included Stainless Steel Laryngeal Ligation Screw Bracket A B Gas Water Valve Power Adapter...
Page 4: ...to respond to different situation after simple set up in Yolink App LED lights can show the current status of device See the explanation below 2 SET Gas Water Valve Model YS4907 UC Power DC12V 1 5A SE...
Page 5: ...Water Valves and action of other devices Voice Control Use Alexa or Google Assistant to control your devices with voice commands YoLink Control No internet required turn on or off your Gas Water Valve...
Page 6: ...Set Up Gas Water Valve Follow the steps below to set up your Gas Water Valve via YoLink App Step 1 Set up YoLink App Get the YoLink App from the Apple App Store or Google Play 4...
Page 7: ...don t have YoLink account tap Sign up for an account and follow the register steps to sign up an account Open the YoLink App Use your YoLink account to log in Step 2 Log in or sign up with YoLink acc...
Page 8: ...me Gas Water Valve You can customize the name set the room add to remove from favourite Tap the in YoLink App Scan the QR Code on the device c Favourite Click icon to add remove the device from Favour...
Page 9: ...d Follow the following page to install the device rst Power on the valve using the supplied power adapter and your device will connect to the cloud automatically Note Make sure you hub is connected to...
Page 10: ...dapter The center axis of the manipulator must be aligned with the center axis of the water pipe valve and the corresponding screw is locked The Valve should not be close to the wall and should be ins...
Page 11: ...Installation Diagram 9...
Page 12: ...will be removed from your account d History Check the history log for the Gas Water Valve 10 e Open Alert Set a time which you will able to receive an alert once your valve has been open for that long...
Page 13: ...hedule to go to its schedules Tap the Gas Water Valve in App to go to its controls Tap icon to add a new schedule Activate or deactivate schedule at the schedule screen Swipe left any schedule for edi...
Page 14: ...ter Tap Timer to go to timer setting 12 Tap the Gas Water Valve in App to go to its controls Set the timer duration in Hours and Minutes Tap icon to save Note One timer will run only once You can set...
Page 15: ...or more devices under this scene and de ne their actions and or states Tap to create your own Scene Tap Smart to switch to Smart Screen Swipe left any Scene order to edit or delete it To execute a Sc...
Page 16: ...y Automation Tap Smart to switch to Smart Screen and tap Automation To set an Automation you will need to set a trigger time local weather condition or choose a device with certain stage as a triggere...
Page 17: ...esponder Receiver You will need to set it up physically Find a sensor as controller Master Hold the power set button for 5 10 seconds the device will enter pairing mode After pairing is done the light...
Page 18: ...hemselves and the light stops ashing Find the responder Receiver Gas Water Valve Hold the set button for 10 15 seconds the light will ash red quickly When the sensor alerts the Gas Water Valve will no...
Page 19: ...YoLink Control Diagram Paired Water Leak Warning turn off turn on Unpaired Water Leak Warning turn on turn on 17...
Page 20: ...ce Highly recommend you could update our newest version rmware Tap Firmware Note The Feature light will be slowly blinking blue during update and stop blinking when update is done Only the Gas Water V...
Page 21: ...ault After the factory reset your device will still in your Yolink account Hold the SET button for 20 25 seconds until the LED blinks red and blue alternately Factory reset will be done when the light...
Page 22: ...ressure 1 6MPa Automatic valve time 5 10 seconds Applicable water pipe size 1 2 inch Dn15 3 4 inch DN20 1 inch DN25 Electric valve opening time 5 10 seconds Environment Working temperature 10 50 14 12...
Page 23: ...reconnect your hub to the Internet and press the set button of the valve once Hub is powered off Timer does not run Please press the button once to turn SET on off you can the valve also turn on off t...
Page 24: ...n commercial applications This warranty does not apply to valves that have been improperly installed modi ed put to a use other than designed or subjected to acts of God such as oods lightning earthqu...
Page 25: ...ne or more of the following measures FCC Statement Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circu...
Page 26: ...other antenna or transmitter FCC RF Radiation Exposure Statement To comply with FCC RF exposure compliance requirements this grant is applicable to only Mobile Con gurations The antennas used for this...