RES = total judgement
Tightening judgement OK or NOK
A: tightening OK
N: tightening NOK
VAL = Output Value
Output value at shut-off
PLS = number of impulses
Number of impulses from Start value to value tool shut-off
INF = tightening result details
Aok = OK
Udr: under, tool shut-off below cut value
Ovr: shut-off at value higher than max value
N55: shut-off at too low number impulses
N57: shut-off at too many impulses
Slw: number of impulses exceeded the slow error impulses(70) including the
number of impulses below start value
Impulse data history
The tool has a memory of the last 5 tightenings with the value of each impulse.
Select PULSE DATA with the Up and Down arrow keys and press ENT to enter this function.
Result: 20 = the average on which the tool has shut-off.
NUM: 6 = number of impulses, including the impulses lower than start value.
6- 12- 15- 19- 20- 21 = the value of each impulse.
If you have a high number of impulses it will not fit on one screen, press NEXT to move to the next or press PREV for previous screen.
Test Mode.
In the test mode the tool can be operated without shut-off. After releasing the trigger, the screen will show the value of each impulse. This function can be used for parameter setting, output
adjustment and tightening analyze (hard or soft joint).
When using this function take care of the CC-1 cable connected to the tool, so it won't entangle with rotating parts or cause dangerous circumstances.
To use this function: Connect the PC-1 to the tool with the CC-1 cable.
Select TEST MODE with the up and down arrow keys and press ENT to enter this function.