![YOKOHAMA ADMAG TI AXFA11G User Manual Download Page 21](http://html.mh-extra.com/html/yokohama/admag-ti-axfa11g/admag-ti-axfa11g_user-manual_911764021.webp)
2-inch Pipe Mounting
2-inch pipe
Mounting fixture
Washer
Clamp screw
F0320.ai
Figure 3.4.4 2-inch Pipe Mounting
1. Pass the four clamp screws through the mounting
fixture.
2. position it on the 2-inch pipe, and then fasten the
AXG1A in place.
Panel Mounting
Panel cutout
172 (6.8)
R3MAX
Mounting fixture
Unit: mm
(approx. inch)
Washer
Screw
Clamp screw
203 (8.0)
F0321.ai
Figure 3.4.5 Panel Mounting
1. Fit the AXG1A into the panel.
2. Attach the mounting fixture to the AXG1A using the
screw and the washer, and secure the instrument with
the two clamp screws.
3.4.4 Mounting of AXFA11 Transmitter
AXFA11 Remote Transmitter can be mounted using
surface mounting, 2-inch pipe mounting, or panel
mounting, by the same process of AXG1A. Please refer
3.4.3. for the process.
IMPORTANT
Mounting fixture on equipment intended to be
mounted on a wall or ceiling shall withstand a force of
four times the weight of the equipment (AXFA11: 3.4
kg (7.5 lb)).
3.5 Changing Direction of
Electrical Connection
3.5.1 Integral Flowmeter
(1) The following tool is required.
• Hexagonal wrench (nominal size 5)
(2) Turn off the power to the flowmeter.
(3) Using the wrench, unscrew the four hexagonal bolts
at the neck of transmitter.
F0322.ai
AXW Integral Flowmeter
CAUTION
Do not loosen the screw at the opposite side of electrical
connection (see the figure below).
F0323.ai
<3. Installation>
20