![YOKOGAWA YFGW510 User Manual Download Page 13](http://html1.mh-extra.com/html/yokogawa/yfgw510/yfgw510_user-manual_3504020013.webp)
13
<Read Me First>
IM 01W02E01-11EN
Explosion Protected Type Specifications
n
Optional Specifications (For Explosion Protected Type)
Item
Description
Code
Factory
Mutual
(FM)
FM Nonincendive Approval
Applicable standards: Class 3600:2011, Class 3611:2004,
Class 3810:2005, NEMA 250:2003
Nonincendive for Class I, Division 2, Groups A, B, C and D; alternatively
for Class I, Zone 2, Groups IIC. Suitable for Class II, Division 2, Groups F
and G; Suitable for Class III, Division 1
Indoor/outdoor Type 4X in hazardous (classified) locations.
Temperature Class T4 at Ta = –40 to 65°C (–40 to 149°F)
Cable parameters for antenna connection:
Ccable: ≤ 4 nF, Lcable: ≤ 20 μH
FN17
Explosionproof Approval
-
Canadian
Standards
Association
(CSA)
CSA Non-Incendive Approval
Certificate: 2655412
Applicable standards: C22.2 No.0-10, CAN/CSA-C22.2 No. 0.4-04,
CAN/CSA-C22.2 No. 94-M91, C22.2 No. 213-M1987,
CAN/CSA-C22.2 No. 60079-0:11,
CAN/CSA-C22.2 No. 60079-15:12,
CAN/CSA-C22.2 No. 61010-1-04, IEC 60529 :2001
Non-Incendive for Class I, Division 2, Groups A, B, C and D;
Class II , Division 2, Groups F and G; Class III, Division I
Non-Incendive Field Wiring Connections for Class I , Division 2,
Groups A, B, C, D;
Ex nA [nL] IIC T4.
Ambient Temperature: –30 to 65 °C (–22 to 149°F), Altitude: ≤ 3000m
Enclosure: Type 4X, IP66
Cable parameters for antenna connection:
Ccable: ≤ 4 nF, Lcable: ≤ 20 μH
CN17
Flameproof Approval
-
ATEX
Type n Declaration
Applicable standard: EN 60079-0:2012+A11:2013, EN 60079-11:2012,
EN 60079-15:2010
II 3 G Ex nA [ic] IIC T4 Gc
Enclosure: IP66
Amb. Temp. (Tamb): –30 to 65°C (–22 to 149°F)
KN27
ATEX Flameproof Approval
Certificate: DEKRA 15ATEX0042 X
Applicable Standard: EN 60079-0:2012+A11:2013, EN 60079-1:2014,
EN 60079-11:2012
II 2 G Ex d [ib] IIC T4 Gb
Um: 250 V
Amb. Temp.(Tamb): -40 to 65°C (-40 to 149°F)
KF27
IECEx
IECEx Type n Approval
Certificate: IECEx DEK 14.0028
Applicable standard: IEC60079-0:2011, IEC60079-11:2011,
IEC60079-15:2010
Ex nA [ic] IIC T4 Gc
Enclosure: IP66
Amb. Temp(Tamb): -30 to 65°C (-22 to 149°F)
SN27
IECEx Flameproof Approval
Certificate: IECEx DEK 15.0021X
Applicable Standard: IEC 60079-0:2011, IEC 60079-1:2007,
IEC 60079-11:2011
Ex d [ib] IIC T4 Gb
Um: 250 V
Amb. Temp.(Tamb): -40 to 65°C (-40 to 149°F)
SF27