<2. General>
2-4
IM 02C01B04-01EN
2.5 Options and Combinations
Options
Item
Description
Code
Kit for elevated-zero or
suppressed-zero ranges
Permits adjustments up to 1000 % of minimum
span and to range limits of capsule. Upper
range-value must not exceed upper range-limit of
capsule.
Elevated-zero
L
Suppressed-zero
R
Air set
Supply pressure: 0.2 to 1 MPa, 2 to 10 kgf/cm
2
or bar, or 30 to 150 psi.
Output pressure: 140 kPa, 1.4 kgf/cm
2
or bar, or 20 psi.
Maximum operating temperature: 80 °C (180 °F). Refer to Table 2.2.
GAS-F
NAS-F
Low differential span
Refer to Table 2.3.
Accuracy ±0.5% of span, ±1.0% of span with code R or L
LD
Cover color other than
standard finish
Specify in color block
by color code. Refer to GS22D01F01-00E.
SCF-
Coating other than standard
finish
Epoxy resin-baked coated.
EPF
Oxygen service
preparation
*1
Degrease cleansing treatment
OSW
Stainless steel bolts and
nuts
JIS SUS 630 bolts and nuts for the body and JIS SUS 630 bolts for process
connectors
SSB
JIS SUS 630 bolts and nuts for the body and JIS SUS 630 bolts for process
connectors and sealant (liquid silicone rubber) are coated on surface of
SUS630 nuts.
SSB-S
Ammonia service
*1
Force bar gasket: Neoprene rubber
AMM
Stainless tube
Tube and connectors between air-set (fixed pressure regulator with filter) and
transmitter are made by stainless steel. However, connection of pressure
gauge remains as standard material (Bs-Ni3).
SST
ANSI connection
Air connections: Tapped for 1/4NPT.
Applicable only for Y/11GM-
S8
NPT
Tropicalization
When there is a possibility to generate rusts using under the condition of
high temperature and high humidity area, silicone grease is coated on whole
screws. Silicon grease which has stronger oil film feature.
PSG
M-calibration
Output signal: 0.2 to 1.0 kgf/cm
2
CAL-M
P-calibration
Output signal: 3 to 15 psi
CAL-E
bar-calibration
Output signal: 0.2 to 1.0 bar
CAL-B
Stainless Tag plate
Stainless Tag plate fixed with screws. Up to 16 characters.
TP-S
Reverse output signal
*2
Reverse output signal
ROUT
*1:
Not applicable for Diaphragm seal.
*2:
Not applicable for option code EPF.
Table 2.2
Air Set
Air Connection
Gauge Scale
Option Code
JIS Rc 1/4
female
0 to 200 kPa
0 to 2 kgf/cm
2
0 to 30 psi
0 to 2 bar
Without gauge
GAS-FP
GAS-FM
GAS-FE
GAS-FB
GAS-F
1/4 NPT female
0 to 200 kPa
0 to 2 kgf/cm
2
0 to 30 psi
0 to 2 bar
Without gauge
NAS-FP
NAS-FM
NAS-FE
NAS-FB
NAS-F
Table 2.3
Low Differential Spans
Capsule
Span
kPa
kgf/cm
2
psi
A
35 to 270
0.35 to 2.8
5 to 40
B
70 to 700
0.7 to 7
10 to 100
C
140 to 1350
1.4 to 14
20 to 200
D
350 to 3400
3.5 to 35
50 to 500
E
700 to 6800
7 to 70
100 to 1000