
5-35
IM XL100C-E
1
2
3
4
5
6
7
App
Index
Standard Protocol
XL
Selects the end trigger
When setting the end trigger to none
Syntax
XL p1<terminator>
p1
End trigger type
None:
0
Query
XL?
Example
Set the end trigger to none.
XL 0
When setting the end trigger to external input
Syntax
XL p1<terminator>
p1
End trigger type
External input:
1
Query
XL?
Example
Set the end trigger to external input.
XL 1
When setting the end trigger to input level
Syntax
XLp1,p2,p3,p4,p5<terminator>
p1
End trigger type
Input level:
2
p2
Channel to be used as the end trigger
Analog CH
For 8 ch input:
01
to
08
For 16 ch input:
01
to
16
Pulse CH:
PL01
Calculation CH:
CA01 to CA32
Communication CH:
CO01 to CO32
p3
End trigger level type
High limit trigger:
H
Low limit trigger:
L
Window IN:
I
Window OUT
:
O
p4
High limit value
-99999
to
99999
p5
Low limit value
-99999
to
99999
Query
XL?
Example
Set the end trigger to low limit 500 of analog
input CH3.
XL 2,03,L,500
Description Set the high and low limits using a five-digit
integer without a decimal point. The decimal
place is the same as the span and scale settings
of the analog input channel.
Be sure to set the high limit greater than the low
limit.
When setting the end trigger to an alarm
Syntax
XL p1,p2
p1
End trigger type
Alarm:
3
p2
Alarm output number to be used as the end
trigger
1
to
4
Query
XL?
Example
Set the end trigger to alarm output number 1.
XL 3,1
When setting the end trigger to a specific time
Syntax
XL p1,p2,p3
p1
End trigger type
Time:
4
p2
End date (YY/MM/DD fixed form)
YY (year):
00
to
99
MM (month):
01
to
12
DD (day):
01
to
31
p3
End time (HH/MM/SS fixed form)
HH (hour):
00
to
23
MM (min):
00
to
59
SS (s):
00
to
59
Query
XK?
Example
Set the end trigger to 4:56:7 on February 3,
2030.
XL 4,30/02/03,04:56:07
When setting the end trigger to a timer
Syntax
XL p1,p2
p1
End trigger type
Timer:
5
p2
End timer (s)
1
to
31536000
Query
XL?
Example
Set the end trigger to a 600-s timer.
XL 5,600
XH
Sets the key login and auto
logout functions
Syntax
XH p1,p2,p3<terminator>
p1
Key login function
Enable:
USE
Disable:
NOT
p2
Timeout function
Enable:
ON
Disable:
OFF
p3
Reserved
Query
XH?
Example
Enable the key login and auto logout functions.
XH USE,ON,
Description Parameter p3 is not used.
XE
Sets whether to save or discard
the settings specified by a basic
setting command
Syntax
XE p1<terminator>
p1
Save or discard settings
Save:
STORE
Discard:
ABORT
Example
Save the settings of the basic setting command.
XE STORE
Description • In order to activate the settings that are
changed using the basic setting commands,
the settings must be saved using the XE
command. If you do not, the settings before
the change are activated if logging is started.
• If the setting command is set to activate when
the settings are saved using the XE command
(the condition which BZ 0 is specified), the
items specified with the setting commands are
activated when the settings are saved using
the XE command.
5.7 Basic Setting Commands