14-9
IM WT5000-01EN
Scheduled Times for Real-Time Integration (Start Time/End
Time)
This setting is valid in real-time normal integration mode and real-time continuous integration mode.
You can set the year, month, day, hour, minute, and second of the integration start and stop times. Be sure to
set the integration stop time to a time after the integration start time. You can set the values within the following
ranges.
• Year: Any four-digit Gregorian calendar value
• Hour:Minute:Second: 00:00:00 to 23:59:59
• Copy Current Time (Copy Current Time): The scheduled integration start time is set to the current time.
• Copy Start Time (Copy Start Time): The scheduled integration start time is copied to the scheduled integration
stop time.
When Independent Integration Is Disabled
The scheduled times that you specified above apply to every element.
When Independent Integration Is Enabled (Scheduled time: Real−time Control)
• Setting (Setting)
You can select the method for setting the scheduled times from the following options.
• Each (Each): Set it separately for each input element.
• All (All): Set it for all installed input elements at the same time.
• Element1 to Element7
You can set the scheduled times for each element within the range given above.
• Copy Current Time (Copy Current Time)
The scheduled integration start time is set to the current time.
• Copy Start Time (Copy Start Time)
The scheduled integration start time is copied to the scheduled integration stop time.
• You can set the day for the scheduled start or stop time in February to a value as high as the 31st day. If
you do so, an error message will appear when you start integration. Reset the scheduled stop time.
• This instrument recognizes leap years when it executes the integration operation.
• In real-time normal integration mode and real-time continuous integration mode, after you tap Start or
press START and this instrument enters into an integration-ready state, the numeric data may not be
updated immediately. This is because the numeric data is updated in sync with the clock of this instrument.
This ensures that the numeric data is updated at the same time as the scheduled integration start time and
that the integration time is accurate.
14 Integrated Power (Watt Hours/Ampere Hours)