![YOKOGAWA WT500 User Manual Download Page 158](http://html.mh-extra.com/html/yokogawa/wt500/wt500_user-manual_911418158.webp)
5-32
IM 760201-01E
5.12 Selecting a Current Integration Mode
Procedure
1.
Press
SETUP
to display the Setup menu.
2.
Use the
cursor keys
to select Integration.
3.
Press
SET
to display the Integration Settings menu.
Selecting a Current Integration Mode
4.
Use the
cursor keys
to select q Mode.
5.
Press
SET
to select rms, mean, dc, r-mean, or ac.
Explanation
Selecting a Current Integration Mode
You can select the type of current whose values will be integrated from one of the
choices listed below. For the integration methods that correspond to these different
current types, see section 2.6.
• rms:
True rms value
• mean:
Rectified mean value calibrated to the rms value
• dc:
Linear average
• r-mean: Rectified mean value
• ac:
AC component
When the current mode is dc, the polarity (+ or -) is displayed.