App-40
IM 760301-01E
Appendix 10 Measurement Modes and Functional
Limitations
The following measurement modes can be used on models with the advanced
computation (/G6), voltage fluctuation and flicker measurement (/FL), or cycle-by-cycle
measurement (/CC) option.The functions that can be used in each measurement mode
are as follows:
Display
Auto range
Averaging
Data update rate
Voltage/Current mode
Peak measurement
User-defined function
MAX hold
Efficiency computation
Compensation
Integration
Store
File save
Zero-level compensation
NULL
Synchronized measurement
Motor
*10
*11
D/A output*
*14
Delta computation*
*15
Mail transmission
*16
Numeric
Waveform
Trend
Bar graph
Vector
Waveform computation
FFT
Flicker
Cycle by Cycle
Exponential average
Moving average
Setup
Wave
Numeric
*8
Acquisition
Print
Auto
Yes
Yes
Yes
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
Yes
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Limit
*13
Yes
Yes
Yes
Yes
Yes
No
No
No
No
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
Yes
*7
Yes
Yes
Yes
Yes
No
Yes
Yes
Limit
*13
Yes
Yes
Yes
No
No
No
No
No
No
No
Yes
No
No
No
No
No
*4
No
No
No
No
No
No
No
No
Yes
No
No
No
Limit
*9
No
No
No
Limit
*12
No
No
No
No
No
No
No
No
No
No
No
No
Yes
No
No
No
No
Yes
No
No
No
No
No
No
No
Yes
No
Yes
No
Limit
*9
No
No
Yes
Limit
*12
No
No
No
No
Yes
*1
No
*2
No
No
*2
No
No
No
No
No
No
Limit
*3
No
No
No
No
No
No
No
Limit
*5
No
No
Yes
No
Yes
No
Yes
No
No
No
Yes
No
No
No
No
Yes
*1
No
No
Yes
Yes
No
No
No
No
Yes
Yes
No
No
No
No
Yes
Yes
No
Limit
*5
No
Limit
*6
Yes
No
Yes
No
Yes
No
No
No
Yes
Limit
*13
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Option
Measurement Mode
Normal
Measurement
Wide Bandwidth
Harmonic
IEC Harmonic Waveform
Computation
FFT
None
/G6, /G5
/G6
/G6
/G6
/G6
/FL
/CC
Harmonics
Yes: Can be used.
Limit: Limitation on some functions.
No: Cannot be used.
*1 The rms values of voltage and current are total values, not the normal measurement values.
*2 Can be monitored using the IEC harmonic measurement software.
*3 The attenuation constant cannot be selected.
*4 Fixed to 2 s.
*5 The efficiency compensation and the compensation for the two-wattmeter method are invalid.
*6 “Integ Sync” cannot be selected, because there is no integration function.Waveform data is set to NAN (no data) if Wave Trace is selected,
because there is no waveform data.
*7 Save FFT waveforms using “Acquisition,” not “Wave.”
*8 If an item that is not measured or computed in the respective measurement mode, NAN data is saved.
*9 The settings can be changed and the function can be executed only when the measurement status is reset.
*10 Requires the motor version (-MV).
*11 Requires the built-in printer option.If an item that is not measured or computed in the respective measurement mode, NAN data is printed.
*12 Only the screen image can be printed.The list cannot be printed.
*13 Integration synchronization (Synchronize) cannot be set.It is fixed to timer.
*14 Requires the D/A output option.
*15 Requires the delta computation option.
*16 Requires the Ethernet communication option.
Voltage
Fluctuation
and Flicker
Cycle by
Cycle