
S-17
IM 760401-01E
Startup GuideS
t
a
r
t
u
p
G
u
id
e
Displaying the Active Power on the Secondary Side of the Inverter on Display C
Carry out the following procedure to display the active power of the secondary side of the
inverter on display C.
V
W
A
B
C
VOLTAGE
AUTO
MODE
CURRENT
AUTO
RANGE
MAX HOLD
TRIG
CAL
INTEGRATOR
INTEG SET
SHIFT
KEY LOCK
1P3W
3P3W
3P4W
3V3A
OUTPUT
HARMONICS
MEMORY
REMOTE
FUNCTION
ELEMENT
HOLD
ENTER
RESET
WIRING
START
STOP
LOCAL
SETUP
1
m
V
k
A
V
TIME
ar
deg
h
h
VA
M
m
PF
k
A
M W
m
V
Hz
k
A
M W
2
3
FUNCTION
ELEMENT
1
2
3
FUNCTION
ELEMENT
1
2
3
%
Function indicator
Element indicator
11.
Press
FUNCTION
of display C to select function W.
For details, see step 5 of page S-14.
12.
Press
ELEMENT
of display C to select input element 1, 3 or
Σ
. When input element
Σ
is
illuminated, the sum of active powers measured on input element 1 and 3 is
displayed. This value is the “power consumed by the load” when computing the
efficiency.
Each time
ELEMENT
is pressed the element indicator character of display C illuminates in the
order shown below. The wiring system of the circuit on the secondary side of the
inverter is three-phase, three-wire, and the circuit is connected to input elements 1 and
3 of the WT230. To show the measured value of input element 1, 3, or
Σ
on display C,
we illuminate input element 1, 3, or
Σ
.
Display C
ELEMENT
ELEMENT
ELEMENT
ELEMENT
1
2
3
Σ
1
2
3
1
2
3
1
2
3
1
2
3
• When input element 1 is illuminated, the active power measured on input element 1 is
displayed.
• When input element 3 is illuminated, the active power measured on input element 3 is
displayed.
• When input element
Σ
is illuminated, the sum of active powers measured on input
element 1 and 3 is displayed. This value is the “power consumed by the load” when
computing the efficiency.
Tips
• The WT210/WT230 is equipped with an input filter function for eliminating noise on
the measured signal and more accurately measuring the frequency of the
measured signal. For the setup procedure, see section 4.3, “Turning ON/OFF the
Input Filter.”
• The WT230 has a function that is used to perform exponential or moving averaging
on the measured values before displaying them when the measured values are not
stable. For the setup procedure, see section 4.7, “Using the Averaging Function.”
Displaying Voltage, Current, and Active Power
Summary of Contents for WT210
Page 1: ...Digital Power Meter IM 760401 01E 3rd Edition ...
Page 208: ...13 18 IM 760401 01E 13 3 Sample Program Image ...
Page 214: ...13 24 IM 760401 01E 13 5 Sample Program Output of Normal Measurement Data ...
Page 266: ...14 50 IM 760401 01E 14 6 Sample Program Image ...
Page 272: ...14 56 IM 760401 01E 14 8 Sample Program Output of Normal Measurement Data ...