S-16
IM 760401-01E
Tips
There are cases when we wish to measure, as a voltage on the secondary side of
the inverter, the converted rms voltage (rectified mean value calibrated to the rms
value) that is derived by summing the absolute values of the voltage over a single
period, dividing the result by the time of one period, and making a conversion. The
WT230 provides a function for measuring the rectified mean value calibrated to the
rms value of only the voltage. For the setup procedure, see section 4.1, “Selecting
the Measurement Mode.”
Displaying the Current on the Secondary Side of the Inverter on Display B
Carry out the following procedure to display the current of the secondary side of the inverter
on display B.
W
A
B
C
VOLTAGE
AUTO
MODE
CURRENT
AUTO
RANGE
MAX HOLD
TRIG
CAL
INTEGRATOR
INTEG SET
SHIFT
KEY LOCK
1P3W
3P3W
3P4W
3V3A
OUTPUT
HARMONICS
MEMORY
REMOTE
FUNCTION
ELEMENT
HOLD
ENTER
RESET
WIRING
START
STOP
LOCAL
SETUP
1
m
V
k
A
V
TIME
ar
deg
h
h
VA
M
m
PF
k
A
M W
m
V
Hz
k
A
M W
2
3
FUNCTION
ELEMENT
1
2
3
FUNCTION
ELEMENT
1
2
3
%
Function indicator
Element indicator
V
9.
Press
FUNCTION
of display B to select function A.
For details, see step 3 of page S-11.
10.
Press
ELEMENT
of display B to select input element 1, 3 or
Σ
.
Each time
ELEMENT
is pressed the element indicator character of display B illuminates in the
order shown below. The wiring system of the circuit on the secondary side of the
inverter is three-phase, three-wire, and the circuit is connected to input elements 1 and
3 of the WT230. To show the measured value of input element 1, 3, or
Σ
on display B,
we illuminate input element 1, 3, or
Σ
.
Display B
ELEMENT
ELEMENT
ELEMENT
ELEMENT
1
2
3
Σ
1
2
3
1
2
3
1
2
3
1
2
3
• When input element 1 is illuminated, the line current of phase U (see page S-6) on the
secondary side of the inverter is indicated.
• When input element 3 is illuminated, the line current of the W phase (see page S-6)
on the secondary side of the inverter is indicated.
• When input element
Σ
is illuminated, the average of the line current of phase U and W
on the secondary side of the inverter is indicated. However, this value does not have
any physical meaning.
Displaying Voltage, Current, and Active Power
Summary of Contents for WT210
Page 1: ...Digital Power Meter IM 760401 01E 3rd Edition ...
Page 208: ...13 18 IM 760401 01E 13 3 Sample Program Image ...
Page 214: ...13 24 IM 760401 01E 13 5 Sample Program Output of Normal Measurement Data ...
Page 266: ...14 50 IM 760401 01E 14 6 Sample Program Image ...
Page 272: ...14 56 IM 760401 01E 14 8 Sample Program Output of Normal Measurement Data ...