14-24
IM 760401-01E
14.3.6 HARMonics Group
The commands in the HARMonics group relate to the harmonic measurement function. This allow you to make the
same settings and inquiries as when using the HARMONICS key on the front panel and the corresponding menus.
This group is only useful in case your instrument is equipped with the /HRM option.
:HARMonics
:
STAT e
<Space>
OFF
ON
<NRf>
?
ELEMent
<Space>
<NRf>
?
SYNChroniz e
<Space>
V
,
<NRf>
ELEMent
<x>
A
?
THD
<Space>
IEC
CSA
?
DISPlay
:
ORDer
<Space>
<NRf>
?
?
?
;
HARMonics?
Function
Queries all settings relating to harmonic
measurement.
Syntax
HARMonics?
Example
HARMONICS? -> :HARMONICS:STATE 0;
ELEMENT 1;SYNCHRONIZE V,1;THD IEC;
DISPLAY:ORDER 1
HARMonics:DISPlay?
Function
Queries all settings concerning the display in
case of harmonic measurement.
Syntax
HARMonics:DISPlay?
Example
HARMONICS:DISPLAY?
HARMONICS:DISPLAY? -> :HARMONICS:
DISPLAY:ORDER 1
HARMonics:DISPlay:ORDer
Function
Sets the order of the harmonic component to be
shown on display B, queries the current setting.
Syntax
HARMonics:DISPlay:ORDer {<NRf>}
HARMonics:DISPlay:ORDer?
{<NRf>}=1 to 50
Example
HARMONICS:DISPLAY:ORDER 1
HARMONICS:DISPLAY:ORDER?
-> :HARMONICS:DISPLAY:ORDER 1
HARMonics:ELEMent
Function
Sets the element for harmonic measurement/
queries the current setting.
Syntax
HARMonics:ELEMent {<NRf>}
14.3 Commands
HARMonics:ELEMent?
{<NRf>}=1
(WT210 single-phase
model)
1, 3
(WT230 three-phase,
three-wire model)
1 to 3 (WT230 three-phase,
four-wire model)
Example
HARMONICS:ELEMENT 1
HARMONICS:ELEMENT?
-> :HARMONICS:ELEMENT 1
HARMonics[:STATe]
Function
Sets the harmonic measurement mode ON/
OFF, queries the current setting.
Syntax
HARMonics[:STATe] {<Boolean>}
HARMonics[:STATe]?
Example
HARMONICS:STATE ON
HARMONICS:STATE? -> :HARMONICS:
STATE 1
Description If you switch the harmonic measurement mode
ON/OFF using this command and query the
measurement mode using the
“
:MEASure:HARMonics:VALue?
” or
“
:MEASure[:NORMal]:Value?
” command
immediately afterwards, the measured data of
the previous measurement mode may be
output. To retrieve the measured data in the
new measurement mode, a wait of
approximately 2 seconds is required after
issuing this command.
Summary of Contents for WT210
Page 1: ...Digital Power Meter IM 760401 01E 3rd Edition ...
Page 208: ...13 18 IM 760401 01E 13 3 Sample Program Image ...
Page 214: ...13 24 IM 760401 01E 13 5 Sample Program Output of Normal Measurement Data ...
Page 266: ...14 50 IM 760401 01E 14 6 Sample Program Image ...
Page 272: ...14 56 IM 760401 01E 14 8 Sample Program Output of Normal Measurement Data ...