
1-14
IM 707281-01E
1.7
Other Functions
Input/Output of Bus Trigger Signals
You can output a signal that is synchronized to the waveform output (trigger output
signal) to the two trigger signal buses (BUSTRG1/BUSTRG2) in the measuring station.
The trigger output signal is set to “True” for approximately 160 ns (typical value*). There
is a time difference of approximately 12.5
µ
s (typical value*) between the trigger output
signal and the bus trigger signal.
In addition, the bus trigger signal can be used as the trigger/gate signal during trigger
oscillation and gate oscillation operations. There is approximately 12.5
µ
s (typical
value*) of delay time from the time the bus trigger signal becomes “True” to the time the
trigger oscillation starts. And, there is a delay of approximately 12.5
µ
s from the time the
bus trigger signal becomes “True” to the time the gate oscillation starts.
* Typical values represent typical or average values. They are not strictly guaranteed.