13-10
IM 05P02D41-01EN
13.1.7 Masking Least Significant Digit of PV Display
Description
With and without least significant digit of the PV in the Operation Display can be set.
If the least significant digit is set to none, the value in the least significant can be
truncated or rounded.
The internal value is not changed depending on whether with or without least significant
digit (the value is for display only). This parameter does not function for the PV without
decimal point.
Least significant digit
is displayed.
Least significant digit
is not displayed.
The following shows the example of with and without least significant digit
PV display
With least significant digit
Without least significant digit
Rounding
Rounding-off
1499.9
1499
1500
1500.4
1500
1500
1999.9
1999
2000
2000.4
2000
2000
3000.0
3000
3000
3000.9
3000
3001
3001.0
3001
3001
Setting Details
Parameter
symbol
Name
Display
level
Setting range
Menu symbol
MLSD
Least significant digital
mask of PV display
STD
OFF: With least significant digit
ON: Without least significant digit
DISP
MKTP
Method for least
significant digital mask
of PV display
STD
0: Rounding
1: Rounding-off
DISP
13.1 Setting Display Functions
Summary of Contents for UP35A
Page 3: ......
Page 15: ...Blank Page...
Page 35: ...Blank Page...
Page 37: ...Blank Page...
Page 47: ...Blank Page...
Page 229: ...Blank Page...
Page 251: ...Blank Page...
Page 317: ...Blank Page...
Page 387: ...Blank Page...
Page 409: ...Blank Page...
Page 411: ...Blank Page...