YOKOGAWA Sushi Sensor Technical Information Download Page 23

22

TI 01W06A51-50EN

Mar.26,2019-00

6. 

Operation and Maintenance

This chapter describes how to carry out daily check of the Sushi Sensor system, carry out 

maintenance when a warning or error occurs, and add and replace wireless system components.

6.1 

Daily Check

To ensure that the wireless communication system continues to operate correctly, it is important 

to monitor the communication stability even after the setup work has been completed and the 

system has started to operate normally. Wireless communication may become unstable if radio 

waves are affected by obstacles in the communication path. Extra attention must be paid when 

a new building is constructed, additional equipment is installed, a temporary structure is built for 

installation or maintenance purposes, or a crane or other heavy vehicle enters the site

6.1.1 

Checking Wireless Communication Status

The application enables you to check the received signal strength indication (RSSI) and the 

packet error rate (PER) of Sushi Sensors. Based on these values, you can check the wireless 

communication status.

You can also use the Sushi Sensor configuration tool, “Sushi Sensor App”, to check the RSSI 

value. For details, refer to the Sushi Sensor user’s manual.

6.1.2 

Gateway Inspection

During gateway inspections, check the installation of the gateway as well as its operation as a 

Sushi Sensor system component.
Check the installation, communication cable connection, and cleanliness of devices.
If any device is dirty or dusty, wipe off dirt or dust using a soft cloth moistened with water or mild 

soap

6.1.3 

Handling a Device in a Warning State

If any device has been judged to be in a warning state, a communication error may occur if the 

status deteriorates even if the application is currently able to acquire sensor values and status 

information.
If a warning message appears due to a low battery level of a Sushi Sensor, replace the battery as 

soon as possible regardless of the displayed number of days. For details about the replacement 

procedure, refer to the Sushi Sensor user’s manual.
If a warning message appears due to a problem related to Sushi Sensor communication 

quality, check whether any phenomena causing a radio propagation failure has occurred in the 

communication path. In addition, check whether any additional structures or vehicles are on 

the path or around the device, and whether any new wireless communication system using the 

same frequency band has begun to be used in the vicinity. For a certain period of time, monitor 

the device for which a warning message is displayed due to a problem related to communication 

quality. If there are no signs that the device may return to the normal state by itself, adjust the 

device arrangement. Adjusting the installation location may cause the device to return to the 

normal state. In addition, when another wireless system is used, improvements can be made by 

changing the radio frequency.

Summary of Contents for Sushi Sensor

Page 1: ...y 8 4 3 Installing the Gateway 9 4 4 Grounding 10 4 5 PoE Power Supply and Connection with the Gateway Configuration PC 10 5 Gateway Setup 11 5 1 Login 11 5 2 Basic Setting of the Gateway 12 5 2 1 Dis...

Page 2: ...may be changed from those of the previous version The contents of this manual are subject to change without prior notice All rights reserved No part of this manual may be reproduced in any form witho...

Page 3: ...rt server and acquire App key Then this encryption key is written to the Sushi Sensor through the NFC function of the Android device Android device can also acquire encryption key via an NFC card Deta...

Page 4: ...application data collection server l Engineering workflow Mar 26 2019 00 Refer to the manual of the Sushi Sensor to be used and the manual of the application data collection server Device delivery Wir...

Page 5: ...or PoE injector Ethernet cable Used to feed power to the gateway and connect to the gateway configuration PC Category Category 5e or higher Environmental resistance Outdoor specifications for outdoor...

Page 6: ...ion to data collection server Attach the provided cable gland to the Ethernet cable regardless of whether the gateway is used indoors or outdoors 1 Remove the cable gland from the main unit 2 Pass the...

Page 7: ...6 at the bottom of the gateway 4 Use a tightening torque of 2 to 3 N m to mount the antennas 3 3 Inserting a SIM Card When using LTE communications via the gateway insert a SIM card If you do not use...

Page 8: ...Ra antenna to antenna connector 1 at the top of the gateway 3 Use a tightening torque of 2 to 3 N m to mount the antenna 3 5 Mounting the GPS Antenna The GPS function of the gateway is not used in the...

Page 9: ...nding environment Check that no damage deformation or foreign objects are affecting or found in the gateway installation location Install the gateway so that the antennas are a sufficient distance awa...

Page 10: ...a diameter of 78 to 101 mm When using a pipe that is any larger or smaller prepare appropriate hose bands separately When installing the gateway in an elevated location watch your step Follow the proc...

Page 11: ...and tighten it using a tightening torque of 1 69 N m 4 5 PoE Power Supply and Connection with the Gateway Configuration PC The power is fed from the PoE switch or the PoE injector to the gateway throu...

Page 12: ...r logging in to the gateway via the Web browser start the setup work The IP address user name and password are required to set up the gateway The factory default settings are as follows IP address 192...

Page 13: ...the DHCP Server The DHCP server function is enabled by default In this section disable the DHCP server When using the DHCP server function of this gateway proceed to the next section 1 Access the gat...

Page 14: ...o comply with the radio laws applicable in each country or region 1 Access the gateway via the Web browser and log in to the gateway 2 Logging in to the gateway opens the Device Information page Check...

Page 15: ...125 2 SF10BW125 Min Datarate 2 SF10BW125 2 SF10BW125 Max Datarate 5 SF7BW125 6 SF6BW125 6 Specify the log related items Change Path of Network Server Logging to var log and Log Level to MAXIMUM 7 Clic...

Page 16: ...notation Delimit each byte using a colon NOTE App EUI is generated from the MAC address of the gateway The MAC address is indicated as NODE on the Device Information page or the nameplate of the gate...

Page 17: ...use LTE communications skip this procedure NOTE Configure the LTE settings with the SIM card inserted 1 Access the gateway via the Web browser and log in to the gateway 2 Click Cellular to display the...

Page 18: ...to the gateway Mask Net mask of the IP address to be set Gateway IP address of the default gateway if necessary Primary DNS Server IP address of the primary DNS server if necessary Secondary DNS Serv...

Page 19: ...tting procedure check the application setting 1 Access the gateway via the Web browser and log in to the gateway 2 Click Apps 3 Check the Enabled check box and click the Launch Node RED button Then th...

Page 20: ...ad eui msg eui ack msg ack appeui msg appeui chan msg chan deveui msg deveui freq msg freq lsnr msg lsnr rfch msg rfch rssi msg rssi seqn msg seqn size msg size timestamp msg time tmst msg tmst return...

Page 21: ...s specified for application engineering 12 Drag the connection point of the function block to connect it to the http request block with a line 13 Drag and drop the debug block from the left pane to th...

Page 22: ...6A51 50EN Mar 26 2019 00 15 Drag the connection point of the function block to connect it to the debug block with a line 16 Click the Deploy button When Successfully deploy is displayed the setting is...

Page 23: ...em component Check the installation communication cable connection and cleanliness of devices If any device is dirty or dusty wipe off dirt or dust using a soft cloth moistened with water or mild soap...

Page 24: ...made redundant by additionally registering a new gateway in Sushi Sensors via an Android device To register a gateway access the network setting of each Sushi Sensor For details refer to the Sushi Sen...

Page 25: ...r is displayed in the list and whether data is received from the Sushi Sensor Item Description EUI EUI 64 address of the Sushi Sensor connected to the gateway Join Time Time at which the Sushi Sensor...

Page 26: ...ppropriate setting value from the table shown below Specify a value that is different from the frequency of the nearby wireless system if possible Item Setting Value Japan EU Additional Channels 922 6...

Page 27: ...ample describes how to store logs using free software named Visual Syslog Server 1 Download Visual Syslog Server from the following URL and install it on the PC you want to store gateway logs on https...

Page 28: ...u Click Debug Options 7 In Remote Syslog configure settings to send logs to the outside of the gateway Item Value Enabled Checked IPAddress IP address of the logging PC 8 Click the Submit button 9 Cli...

Page 29: ...28 TI 01W06A51 50EN Revision Information Title LoRaWAN Gateway Setup Guide Manual number TI 01W06A51 50EN Edition Date Revised Item 1st March 2019 New issue Mar 26 2019 00...

Reviews: