1-23
IM 04P03B01-01E
Functional Explanation and Setup Guide
1
1.6
Function Setup Guide
This section explains the settings necessary to use various functions of the recorder.
Read the section corresponding to the function you wish to use.
Note
This section contains all the settings related to each item. If the desired setting is the same as
the default value, you do not have to set it.
Item
Description
Reference
Section
Date/Time setting
Use
CLOCK
in Setting mode
2.5
DST
Sets the date/time for switching between DST and standard time using
3.14
AUX > DST
in Setting mode.
Setting initialization
Use
INIT
in Basic Setting mode to initialize the settings of Setting mode
4.17
and Basic Setting mode to their default values.
Measuring input functions
Item
Description
Reference
Section
Range and span of the TC, RTD, or DC voltage
Use
RANGE
in Setting mode.
2.1
1-5V
• Range, span, and scale
2.1
Use
RANGE
in Setting mode.
• Unit
2.3
Use
UNIT
in setting mode to set the unit after scaling.
• Low-cut
4.15
Use
PERS. > 1-5V
low-cut in Basic Setting mode and select Use or Not.
If Use is selected, turn ON/OFF the low-cut function using
RANGE
in Setting
2.1
mode.
If Not is selected, the Low-cut item does not appear in the
RANGE
setting.
Scaling
• Range, span, and scale
2.1
Use
RANGE
in Setting mode.
• Unit
2.3
Use
UNIT
in setting mode to set the unit after scaling.
Square Root Computation • Range, span, and scale
2.1
Use
RANGE
in Setting mode.
• Unit
2.3
Use
UNIT
in setting mode to set the unit after scaling.
• Low-cut
4.15
Use
PERS. >
SQRT
low-cut in Basic Setting mode and select Use or Not.
If Use is selected, set the low-cut value using
RANGE
in Setting mode.
2.1
If Not is selected, the Low-cut item does not appear in the
RANGE
setting.
Unused channels
Use
RANGE
>
SKIP
in Setting mode to disabling the trend recording (dot model)
2.1
and periodic printout of the target channel.
Bias
Use
PERS.
>
BIAS
in Basic Setting mode and select Use or Not.
4.15
If Use is selected, set the bias value that is added to the input using
BIAS
in
3.10
Setting mode. If Not is selected, the
BIAS
item does not appear.
Calibration Correction (/CC1 option)
Use
PERS. > CALIB
in Basic Setting mode and select Use or Not
4.15
If Use is selected,
• Use
CALIB
in Basic Setting mode to set the correction mode and the number
4.22
of calibration points.
• Use
CALIB
in Setting mode to set the measured value and correction value
3.11
for each channel.
If Not is selected, the
CALIB
item does not appear.
Burnout detection function (TC input and 1-5V input)
4.3
Use
B_OUT
in Basic Setting mode to set the burnout detection function for each
channel.