Introduction

Thank you for purchasing the S GX10/GX20/GP10/GP20 (hereafter referred to 

as the GX or GP) or the GM.

This manual describes the operating procedure for the GX/GP/GM OPC-UA server (/

E3 option). Please use this manual in conjunction with the standard user’s manual (IM 

04L51B01-01EN (GX/GP) or IM 04L55B01-01EN (GM)).

To ensure correct use, please read this manual thoroughly before beginning operation.

The following manuals are provided for the GX/GP/GM.

●  Paper Manuals 

Model

Manual Title

Manual No.

Description

GX/GP

Model GX10/GX20/GP10/GP20

Paperless Recorder

First Step Guide

IM 04L51B01-02EN

Explains the basic operations of the GX/GP.

GM

Data Acquisition System GM

First Step Guide

IM 04L55B01-02EN

Explains the basic operations of the GM.

●  Downloadable Electronic Manuals

You can download the latest manuals from the following website.

www.smartdacplus.com/manual/en/

Model Manual Title

Manual No.

Description

GX/GP Model GX10/GX20/GP10/GP20

Paperless Recorder 

First Step Guide

IM 04L51B01-02EN

This is the electronic version of the paper manual.

Model GX10/GX20/GP10/GP20

Paperless Recorder

User’s Manual

IM 04L51B01-01EN

Describes how to use the GX/GP. The communication 

control commands and some of the options are excluded.

Model GX10/GX20/GP10/GP20

Advanced Security Function (/AS)

User’s Manual

IM 04L51B01-05EN

Describes how to use the advanced security function (/

AS option).

GM

GM Data Acquisition System

First Step Guide

IM 04L55B01-02EN

This is the electronic version of the paper manual.

GM Data Acquisition System

User’s Manual

IM 04L55B01-01EN

Describes how to use the GM. The communication 

control commands and some of the options are excluded.

GM Data Acquisition System

Advanced Security Function (/AS)

User’s Manual

IM 04L55B01-05EN

Describes how to use the advanced security function (/

AS option).

GX/GP

GM

Model GX10/GX20/GP10/GP20/GM10

Communication Commands

User’s Manual

IM 04L51B01-17EN

Describes how to use command control communication 

functions.

S STANDARD

Universal Viewer

User’s Manual

IM 04L61B01-01EN

Describes how to use Universal Viewer, which is a 

software that displays GX/GP/GM measurement data 

files.

S STANDARD

Hardware Configurator

User’s Manual

IM 04L61B01-02EN

Describes how to use the PC software for creating setting 

parameters for various GX/GP/GM functions.

Model GX10/GX20/GP10/GP20/GM10

Multi-batch Function (/BT)

User’s Manual

IM 04L51B01-03EN

Describes how to use the multi batch function (/BT 

option).

Model GX10/GX20/GP10/GP20/GM10

Log Scale (/LG)

User’s Manual

IM 04L51B01-06EN

Describes how to use the log scale (/LG option).

Model GX10/GX20/GP10/GP20/GM10

EtherNet/IP Communication (/E1)

User’s Manual

IM 04L51B01-18EN

Describes how to use the communication functions 

through the EtherNet/IP (/E1 option).

Model GX10/GX20/GP10/GP20/GM10

WT Communication (/E2)

User’s Manual

IM 04L51B01-19EN

Describes how to use WT communication (/E2 option).

Model GX10/GX20/GP10/GP20/GM10

OPC-UA Server (/E3)

User’s Manual

IM 04L51B01-20EN

Describes how to use the OPC-UA server function (/E3 

option).

Model GX10/GX20/GP10/GP20/GM10

SLMP Communication (/E4)

User’s Manual

IM 04L51B01-21EN

Describes how to use SLMP communication function (/

E3 option).

Model GX10/GX20/GP10/GP20/GM10

Loop Control Function, Program Control 

Function (/PG Option)

User’s Manual

IM 04L51B01-31EN

Describes how to use the Loop Control Function, 

Program Control Function (/PG Option).

GX/GP DXA170

DAQStudio

User’s Manual

IM 04L41B01-62EN

Describes how to create custom displays (/CG option).

 

5th Edition: July 2021 (YK)

All Rights Reserved, Copyright  © 2015, Yokogawa Electric Corporation

Summary of Contents for SMARTDAG+ GX10

Page 1: ...User s Manual IM 04L51B01 20EN 5th Edition Model GX10 GX20 GP10 GP20 GM10 OPC UA Server E3 User s Manual...

Page 2: ......

Page 3: ...cquisition System Advanced Security Function AS User s Manual IM 04L55B01 05EN Describes how to use the advanced security function AS option GX GP GM Model GX10 GX20 GP10 GP20 GM10 Communication Comma...

Page 4: ...Trademarks SMARTDAC is registered trademarks of Yokogawa Electric Corporation Microsoft and Windows are registered trademarks or trademarks of Microsoft Corporation in the United States and other cou...

Page 5: ...ion GX GP User s Manual Model GX10 GX20 GP10 GP20 Paperless Recorder User s Manual Refers to the IM 04L51B01 01EN GX GP First Step Guide Model GX10 GX20 GP10 GP20 Paperless Recorder First Step Guide R...

Page 6: ...ons that could cause light injury to the user or cause damage to the instrument or user s data and precautions that can be taken to prevent such occurrences Note Calls attention to information that is...

Page 7: ...number 1 3 GX GP Release number 4 Version 4 01 Support for PID control module has been added Style number 2 GM10 Release number 4 Version 4 01 Style number 1 4 GX GP Release number 4 Version 4 08 Supp...

Page 8: ...Overview 1 1 OPC UA Server E3 Specifications 1 2 Communication Specifications 1 2 Security 1 3 GX GP GM Configuration 1 5 OPC UA Server Function 1 5 Others 1 5 GX GP GM Data Structure 1 6 Entire Stru...

Page 9: ...m that is linked to production sites to grasp and manage production process status provide instructions and aid to operators and the like Features Incorporation of the OPC UA server function allows ea...

Page 10: ...r type Data Access Server DA Profile Micro Embedded Device Server Maximum number of items GX20 GP20 GM10 300 MonitoredItem Session GX10 GP10 100 MonitoredItem Session Maximum number of subscriptions 3...

Page 11: ...tion Method Description Anonymous authentication No authentication Username authentication Authentication by user name1 2 and password1 1 The user name and password set with the GX GP GM security func...

Page 12: ...User Only data reading is allowed Read Admin Data reading and writing are allowed Read Write SecondAdmin1 Only data reading is allowed Read Monitor 1 Only data reading is allowed Read 1 Only for the...

Page 13: ...ion Description On The OPC UA server function is enabled Off The OPC UA server function is disabled Port number Set the port that the OPC UA server will use Unless specified otherwise you do not need...

Page 14: ...an OPC UA server An OPC UA client can access a GX GP GM and view the address space in order to write and read from required nodes monitor data and so on Entire Structure Device GX10 1 IP address or ho...

Page 15: ...hannel data Float Read Write All Alarm Status Status of all alarms Boolean Read Only If any alarm status is true this is set to true Alarm Status 1 to 4 Status of each alarm Boolean Read Only Alarm SP...

Page 16: ...Communication channel 0001 All channel alarm status Alarm level 1 status Alarm level 2 status Alarm level 3 status Alarm level 4 status Channel data C0001_Setting C0001_Alarm_Setting C0001_Alarm01_SP...

Page 17: ...hannel I O channel 0001 All channel alarm status Alarm level 1 status Alarm level 2 status Alarm level 3 status Alarm level 4 status Channel data CH0001_Setting CH0001_Alarm_Setting CH0001_Alarm01_SP...

Page 18: ...0 Math channel 0001 All channel alarm status Alarm level 1 status Alarm level 2 status Alarm level 3 status Alarm level 4 status Channel data A0001_Setting A0001_Alarm_Setting A0001_Alarm01_SP A0001_A...

Page 19: ...alue SP value OUT value RUN STOP switching AUTO MAN Cascade switching LOCAL REMOTE switching LP001_ALARM LP001_ALARM01 LP001_ALARM02 Alarm level 1 status in the loop LP001_ALARM03 LP001_ALARM04 Alarm...

Page 20: ...nt01 Batch_Comment01_02 Batch_Comment01_03 Batch_No01 Batch_Group01 Batch_Comment01_01 Batch Settings Batch comment 1 Batch comment 2 Batch comment 3 Batch number Batch_Text01_01 Batch_TextField01_01...

Page 21: ...rver but data values and status vary depending on the GX GP GM channel data and channel status The data values and status that can be acquired depending on the channel status are shown below GX GP GM...

Page 22: ...ription Supported Functions Group Sub Group Supported Function Subscription Notification Data Change Notification Max Subscription 3 Subscription Session Min Publish Interval 100 ms Lifetime Count 3 t...

Reviews: