YOKOGAWA JUXTA VJ Series User Manual Download Page 1

Model VJUK

Limit Alarm for Universal 

Input

 •

Input resistor (shunt resistor): 1 pc. (100 Ω: E9786WD) 

(when model code 1 and input signal A are specified)

 •

Input resistor (shunt resistor): 1 pc. (100 Ω: E9786WD) 

(when the /R100 option is specified)

 •

Input resistor (shunt resistor): 1 pc. (250 Ω: E9786WE) 

(when the /R250 option is specified)

 •

User’s manual (IM 77J01U21-01E, this manual): 1 copy

 •

User’s manual (IM 77J01A00-91Z1): 1 copy

GENERAL

The VJUK is a plug-in type alarm setting device that receives 

voltage/current, thermocouple/RTD, or mV signal as an input signal.

 •

Various parameters can be changed from a PC (VJ77).

MODEL AND SUFFIX CODES

Model

Suffix codes

Description

VJUK

-x

2

x -x

T 0 0

/x

Limit Alarm for Universal Input

Model 

code

-1

DC input type (voltage and 

current input)

*1

-2

DC current input type (with 

transmitter power supply)

*2

-3

Temperature input type

*3

Output

configuration

2

2 outputs

Power supply

6

100-240 V AC/DC

*4

7

15-30 V DC

*5

Input signal

-6

1 to 5 V DC

-A

4 to 20 mA DC

-U

Thermocouple, RTD, or mV 

signal; voltage or current

*6

Output signal

T

Alarm output (2 relay contact 

points)

Fixed code

0

Always 0

Fixed code

0

Always 0

Option

/SN

No socket (with socket if not 

specified)

/C0

HumiSeal coating

*7

/FB

Fuse bypass

*7

/RJCN

No RJC sensor (with RJC 

sensor if not specified)

*8

/R100

With 100 Ω input resistor

*9

/R250

With 250 Ω input resistor

*9

/DF

Fahrenheit display function

*1: Input signal can be selected from 6, A, and U.

*2: Input signal is fixed to A.

*3: Input signal is fixed to U.

*4: Operating range: 85 to 264V AC/DC

*5: Operating range: 12 to 36V DC

*6: When the model code is 1, the input signal is voltage and current.

When the model code is 3, the input signal is thermocouple, RTD, and mV signal.

*7: When option code /C0 or /FB is specified, the conformity to the safety 

and EMC standards is excluded. CE marking is not applicable.

*8: The /RJCN option can be selected when the model code is 3.

*9: 

The /R100 and /R250 options can be selected when the input signal is U.

Note: An exclusive User’s Manual might be attached to the 

products whose suffix codes or option codes contain the code 

“Z” (made to customers’ specifications). Please read it along 

with this manual.

CAUTIONARY NOTES FOR SAFE USE OF THE 

PRODUCT

This User’s Manual should be carefully read before installing 

and operating the product. Please keep this User’s Manual for 

future reference. 

For more information of the safety precautions, 

please refer to the “Precautions on the Use of the JUXTA Series (IM 

77J01A00-91Z1)”. The related manuals and general specifications 

are shown in the table below.

Doc. Name

Doc. Number 

Precautions on the Use of the JUXTA Series (User’s Manual) IM 77J01A00-91Z1

Model VJUK Limit Alarm for Universal Input (User’s 

Manual)

IM 77J01U21-01E

(This manual)

Model VJUK Limit Alarm for Universal Input (General 

Specifications)

GS 77J01U21-01E

User’s manuals in the above table are essential parts of the 

product; keep it in a safe place for future reference.

This manual is intended for the following personnel;   

 •

Engineers responsible for installation, wiring, and maintenance 

of the equipment.

 •

Personnel responsible for normal daily operation of the 

equipment.

The following symbol is used on the product and in this manual to 

ensure safe usage.

 WARNING

Calls attention to actions or conditions that could 

cause serious or fatal injury to the user, and indicates 

precautions that should be taken to prevent such 

occurrences.

 CAUTION

Calls attention to actions or conditions that could 

cause injury to the user or damage to the instrument 

or property and indicates precautions that should be 

taken to prevent such occurrences.

QR Code

The product has a QR Code pasted for efficient plant 

maintenance work and asset information management.

It enables confirming the specifications of purchased products 

and user’s manuals.

For more details, please refer to the following URL.

https://www.yokogawa.com/qr-code

*  QR Code is a registered trademark of DENSO WAVE 

INCORPORATED.

CHECKING THE PRODUCT  SPECIFICATIONS 

AND THE CONTENTS OF PACKING

(1) Model and Specifications Check 

  Check that the model and specifications indicated on the 

nameplate attached to the side face of the main unit are as 

ordered. 

(2) Contents of the Package

  Check that the package contains the following items: 

 •

VJUK: 1  unit

  Standard Accessories: 

 • Tag number label: 1 pc.

 •

Range label: 1 sheet (when model code 1 or 3 is specified)

 •

RJC sensor (A1167HT): 1 pc. (when optional code RJCN is 

not specified) (when model code 3 is specified)

IM 77J01U21-01E

3rd Edition: Mar. 2021

User’s

Manual

1

Thank you for purchasing the JUXTA Signal Conditioner.

Please read through this manual before use for correct handling.

2-9-32, Naka-cho Musashino-shi, Tokyo 180-8750 Japan

http://www.yokogawa.com/ns/juxta/im/

You can download the latest manuals from the following website:

Reviews: