<1. GENERAL>
1-1
IM 11G02Q02-01EN 2nd Edition : Sep. 04, 2020-00
1. GENERAL
This product provides a communication function through RS-485 interface, which allows data
transmit to or receive from the host computer and other devices.
The communication system is comprised of a master station and slave stations. Up to 31 of slave
station (present instrument) can be connected per master station (host computer, programmable
controller, graphic display panel, etc.) through RS-485 interface.
Because the master station can communicate with only one slave station at a time, the
destination can be identified by the “Station No” set for each slave station.
In order that the master station and the slave station can communicate, the format of the
transmit/receive data must coincide. The format of the communication data is determined by the
MODBUS protocol
[RS-232 <=> RS-485 converter] (recommended )
Type:
KS-485 (non-isolated type)/SYSTEM SACOM Corp.
Type:
SI-30FA (isolated type)/SEKISUI ELECTRONICS Co., Ltd.
[USB <=> RS-485 converter] (recommended article)
Type:
USB-485I / SYSTEM SACOM Corp.
RS-485
USB
RS-485
RS-232C
RS-485
RS-485
Programmable controller
Converter
IR202
IR202
RS-232C or USB
Figure1.1
Configuration between master and slave devices