<2. SPECIFICATIONS>
2-5
IM 12E04A02-02E
9th Edition : Mar. 16, 2018-00
2.3 Model and Suffix Codes
[Style: S3]
Model
Suffix Code
Option Code
Description
TB400G ....................................
................
Surface Scattering Light Turbidity Meter
Output
-4
-5
................
................
4 to 20 mA DC
1 to 5 V DC
Power supply
-1
-3
-6
-7
................
................
................
................
100 V AC, 50/60 Hz
110 V AC, 50/60 Hz
200 V AC, 50/60 Hz
220 V AC, 50/60 Hz
Device
configuration and
Application
-NN
-A1
-A2
-A3
-KC
................
................
................
................
................
Without sampling system, automatic cleaning, or automatic zero calibration *1
With sampling system, but without automatic cleaning or automatic zero calibration
With sampling system and automatic cleaning, but without automatic zero calibration
With sampling system, automatic cleaning, and automatic zero calibration
For Korea. Without sampling system. (without cleaning,without auto.zero calibration) *8
Optional
specification
Mounting bracket
Piping
Stanchion material
Bubble treatment
Tag plate
Combination analyzer
Arrester
PSL calibration
/P
/R
/B
/S
/L
/SCT
/PHN5
/PHU5
/TT3
/FC
/ARS
/PSL
Mounting bracket: For pipe mounting *2
Mounting bracket: For rack mounting *2
Tie-in with rear piping *3
Stainless steel stanchion *3
Bubble retardant for low range *3 *4
Stainless steel tag plate
With PH450G pH meter (without ultrasonic cleaning) *3 *5
With PH450G pH meter (with ultrasonic cleaning) *3 *5
With 500 mL KCl reserve tank for pH sensor *5
With non-reagent type free available chlorine analyzer *3 *5
With arrester *6
Calibration using polystyrene latex *7
*1:
A de-foaming tank (head tank) is to be provided. It is to be installed to adjust the sample flow to the detector at 1.5 to 2 L/min.
*2:
These options are available for the specification of “without sampling system” (suffix code: -NN, -KC).
*3:
These options are available for the specification of “with sampling system” (suffix code: -A1, -A2 or -A3).
*4:
When measuring range is low (200 mg/L or less) and if air bubbles are likely to be formed on the sample, this option is to be specified.
When measuring range is high (more than 200 mg/L), this option is not to be specified. Because air bubbles in high ranges don’t disturb
the measurement, and because clogging or reduction of flow rate may occur at the removal port of air bubbles on the flow line.
*5:
A pH meter with necessary units, or non-reagent type free available chlorine analyzer should be purchased separately.
Both of a pH meter and non-reagent type free available chlorine analyzer can not be installed together on the TB400G.
Available model & suffix codes are as follows;
Non-reagent type free available chlorine analyzer (refer to the GS 12F5A1-E)
FC400G-□
-
□*A/ST (for /FC)
* The power supply of FC400G is to be suitable for the power supply of TB400G.
pH meter (refer to the GS 12B07B02-E, GS 12J05C02-00E and GS 12B07C05-01E)
pH sensor
PH8EFP-03-TN-TT1-N-G*A (for /PHN5 or /PHU5, without /TT3)
PH8EFP-03-TN-TT3-N-G*A (for /PHN5 or /PHU5, and /TT3)
pH holder
PH8HF-PP-JPT-T-NN-NN*A (without cleaning) (for /PHN5)
PH8HF-PP-JPT-T-S3-C1*A (with ultrasonic cleaning) (for /PHU5)
pH converter
PH450G-A-J (for /PHN5 or /PHU5)
Ultrasonic oscillator
PUS400G-NN-NN-□
-J
* The power supply of PUS400G is to be suitable for the power supply of TB400G.
*6:
This option is not available for the options of /PHN5, /PHU5 or /FC.
*7:
Polystyrene latex solution of which concentration is 2 degrees is used as a standard solution to calibrate the TB400G.
Without this option, the standard TB400G is calibrated with a Kaolin solution.
*8:
No additional specifications other than “/P”,”/R” and “/SCT” can be chosen.
2.4 Accessories
Item
Quantity
Remarks
Standard calibration plate
1
Housed in the converter
Silicone cloth
1
Lamp
1
As a spare
Fuse
4 each
1 A and 3 A (as spares)
Pipe mounting bracket (optional)
1 set
When specifying option code "/P"
Rack mounting bracket (optional)
1 set
When specifying option code "/R"
Soft PVC tube, 1 m
2
For detector piping (for without sampling system)
Clamp
2
For detector piping (for without sampling system)