5-202
IM DLM4038-17EN
:SERialbus<x>:PSI5:DETail?
Function
Queries all PSI5 signal analysis list settings.
Syntax
:SERialbus<x>:PSI5:DETail?
<x> = 1 to 4
:SERialbus<x>:PSI5:DETail:DISPlay
Function
Sets or queries the display mode for the PSI5
signal analysis list.
Syntax
:SERialbus<x>:PSI5:DETail:DISPlay {F
ULL|LOWer|UPPer}
:SERialbus<x>:PSI5:DETail:DISPlay?
<x> = 1 to 4
Example
:SERIALBUS1:PSI5:DETAIL:DISPLAY FULL
:SERIALBUS1:PSI5:DETAIL:DISPLAY?
-> :SERIALBUS1:PSI5:DETAIL:DISPLAY F
ULL
:SERialbus<x>:PSI5:DETail:LIST:ALL?
Function
Queries all the data for all analysis numbers in
the PSI5 signal analysis result list.
Syntax
:SERialbus<x>:PSI5:DETail:LIST:ALL?
<x> = 1 to 4
Example
:SERIALBUS1:PSI5:DETAIL:LIST:ALL?
-> #8
(8-digit number of bytes)(data sequence)
Description All the data for all analysis numbers are returned
in <block data> format.
The data of each analysis number is separated
by ASCII code 0AH.
:SERialbus<x>:PSI5:DETail:LIST:ITEM?
Function
Queries all items that will be displayed in the
PSI5 signal analysis result list.
Syntax
:SERialbus<x>:PSI5:DETail:LIST:ITEM?
<x> = 1 to 4
Example
:SERIALBUS1:PSI5:DETAIL:LIST:ITEM?
-> :SERIALBUS1:PSI5:DETAIL:LIST:IT
EM "No.Time(ms)Slot No.DataParity/
CRCInformation"
:SERialbus<x>:PSI5:DETail:LIST:VAL
ue?
Function
Queries all the data for the specified analysis
number in the PSI5 signal analysis result list.
Syntax
:SERialbus<x>:PSI5:DETail:LIST:VAL
ue? {<NRf>|MAXimum|MINimum}
<x> = 1 to 4
<NRf> = −400000 to 400000
Example
:SERIALBUS1:PSI5:DETAIL:LIST:VAL
UE? 1
-> :SERIALBUS1:PSI5:DETAIL:LIST:VAL
UE "1, 0.062104,1,AB67,2,,,"
:SERialbus<x>:PSI5:SEARch?
Function
Queries all PSI5 signal search settings.
Syntax
:SERialbus<x>:PSI5:SEARch?
<x> = 1 to 4
:SERialbus<x>:PSI5:SEARch:ABORt
Function
Aborts the PSI5 signal search.
Syntax
:SERialbus<x>:PSI5:SEARch:ABORt
<x> = 1 to 4
Example
:SERIALBUS1:PSI5:SEARCH:ABORT
:SERialbus<x>:PSI5:SEARch:EXECute
Function
Executes a PSI5 signal search.
Syntax
:SERialbus<x>:PSI5:SEARch:EXECute
<x> = 1 to 4
Example
:SERIALBUS1:PSI5:SEARCH:EXECUTE
:SERialbus<x>:PSI5:SEARch:SELect
Function
Sets which detected point to display in the PSI5
signal search zoom window and queries the
zoom position of the detected point.
Syntax
:SERialbus<x>:PSI5:SEARch:SELe
ct {<NRf>|MAXimum}
:SERialbus<x>:PSI5:SEARch:SELect?
<x> = 1 to 4
<NRf> = 0 to 49999
Example
:SERIALBUS1:PSI5:SEARCH:SELECT 1
:SERIALBUS1:PSI5:SEARCH:SELECT?
-> :SERIALBUS1:PSI5:SEARCH:
SELECT 1.50000000
Description If there are no detected points, the DLM4000
returns “NAN.”
:SERialbus<x>:PSI5:SEARch:SETup?
Function
Queries all PSI5 signal search condition settings.
Syntax
:SERialbus<x>:PSI5:SEARch:SETup?
<x> = 1 to 4
:SERialbus<x>:PSI5:SEARch[:SETup]:DA
TA?
Function
Queries all PSI5 signal data search settings.
Syntax
:SERialbus<x>:PSI5:SEARch[:SETup]:DA
TA?
<x> = 1 to 4
:SERialbus<x>:PSI5:SEARch[:SETup]:DA
TA:DATA?
Function
Queries all data settings of the PSI5 signal data
search.
Syntax
:SERialbus<x>:PSI5:SEARch[:SETup]:
DATA:DATA?
<x> = 1 to 4
5.25 SERialbus Group