1-3
IM AQ6376-01EN
Functions
1
2
3
4
5
6
7
8
9
10
11
App
Index
1.2 Measurement
Segment Measurement <<See section 4.13 for the operating procedure>>
This function allows you to divide up items to be measured in units of previously specified
segments.
Allows measurement delimited by segments (portions).
Smoothing <<See section 4.18 for the operating procedure>>
This function attenuates the noise in the measured waveform. By using the Smoothing
function, areas on the waveform with a large amount of noise can be “smoothed out”
when measured.
One-Action Keys <<See section 4.4 to 4.6, 5.1 and 5.9 for the operating
procedure>>
This is the general name for a key that uses data from the active trace waveform (the
currently displayed waveform) to set measurement conditions.
Setting conditions requires that a waveform is displayed for the active trace.
One-Action Key Name
Description
PEAK → REF LEVEL
Sets the peak level of the measured waveform of the active trace
as the reference level.
MARKER→ REF LEVEL
Sets the moving marker level as the reference level.
PEAK→CENTER
Sets the peak wavelength (frequency / wavenumber) of the active
trace measurement waveform to center wavelength (frequency /
wavenumber)
MEAN WL→CENTER
Sets THRESH 3 dB center wavelength (frequency / wavenumber)
of the active trace measured waveform to center wavelength
(frequency / wavenumber).
VIEW→MEAS
Sets the currently displayed ZOOM scale
as the measurement
scale (CENTER, START, STOP, SPAN) for the next sweep.
MARKER →CENTER
Sets the wavelength (frequency / wavenumber) of the moving
marker to center wavelength (frequency / wavenumber).
Δλ→SPAN
Sets the
sweep width as six times the RMS 20 dB width of the
active trace measurement waveform.
MKR L1-L2 →SPAN
Sets spacing between line markers 1 and 2 for sweep width.
PEAK
→ZOOM
CTR
Sets the peak wavelength (frequency / wavenumber) of the active
trace measurement waveform to center wavelength (frequency /
wavenumber) of zoom display.
MARKER →ZOOM CTR
Sets the wavelength (frequency / wavenumber) of the moving
marker to center wavelength (frequency / wavenumber) of zoom
display.
MKR L1-L2 →ZOOM SPAN
Sets spacing between line markers 1 and 2 for sweep width of
zoom display.
Switching between Vacuum Wavelength and Air Wavelength
<<See section 4.2 for the operating procedure>>
This function switches the measured wavelength to either a vacuum wavelength or an air
wavelength.
Measurement can be performed in either air or vacuum wavelength mode.
Switching among Wavelength, Frequency and Wavenumber
<<See section 4.2 for the operating procedure>>
This function switches the horizontal axis display to wavelength / frequency /
wavenumber.
You can display either the wavelengths or frequencies of marker values and analysis
results.