![YOKOGAWA AF220 Application Note Download Page 9](http://html1.mh-extra.com/html/yokogawa/af220/af220_application-note_3466552009.webp)
F²MC-16LX Family, Flash Programmer Yokogawa AF220/221
www.cypress.com
Document No. 002-05108 Rev. *B
9
2
Hardware Set-up
This chapter describes how to set up the programmer
2.1
Hardware Configuration
The right PC-card (for Cypress 16LX-series: FF201) has to be inserted in the card slot of the programmer. Of course,
the power connection with the external power-adapter and the connection to the target board via the interface cable
have to be done, too.
After switching on the power supply, an internal system-check is done and the used control module name is
displayed.
In case that another microcontroller wants to be used, another Micom Pack has to be used.
2 . 1 . 1
C h a n g i n g t h e M C U s e r i e s
In order to change the microcontroller type the latest Micom Pack including the module parameter file (*.prm) and
write control program (*.BTP), means bootloader-kernel, has to be downloaded from
The *.BTP file is like a bootloader-kernel and is always related to a special microcontroller series.
1. Download latest Micom Pack regarding to your microcontroller-series.
2. Remove PC-card from Yokogawa Programmer.
3. Insert PC-card to Personal Computer with an enabled PC-card slot.
Note:
In order to enable access to the PC-card the PC-card driver of Windows has to be installed on your PC. Add the
following lines to the config.sys in order to find the PC-card as a drive within the Widows-Explorer:
device=c:\windows\system\csmapper.sys
device=c:\windows\system\carddrv.exe/slot=2
4. Copy the write control program (*.BTP) to PC-card.
5. Remove PC-card from Personal Computer.
6. Insert PC-card to Yokogawa Programmer.
If no PC with PC-card slot is available then the BTP-file can be exchanged using the Remote software package
AZ290 (see chapter 4):
The old BTP-file has to be erased by the command File Purge[FUNC] + F 3 in the tab Basic-Operation. Afterwards
the new BTP-
file can be copied by using the function “Bundle-File: File Copy from HD to DOS area” from the tab File-
Transfer.
Note:
Only one write control program (*.BTP) is allowed to be stored on the PC-card!
In case that more than one BTP-file is located on the PC-card the programming might fail!