5. BASIC OPERATING PROCEDURES
IM 1E7B0-02E
5-9
5.2.3
Alarm Display Mode
• When an alarm occurs, an alarm number indicating is displayed in place of the normal
display mode.
However, this happens only when the current display mode is the flow rate data display
mode or when parameter number are being changed in the setting mode. (Alarms are not
displayed when data items are being changed.)
Flow rate data displayed
4 seconds
Alarm 06 is displayed
2 seconds
Flow rate data is displayed
4 seconds
Alarm 20 has occurred
2 seconds
Flow rate data is displayed
4 seconds
Alarm (Err) 06 and Alarm (Err) 20 have occurred
Alarm (Err) 06 has occurred
Flow rate data displayed
4 seconds
Alarm 06 is displayed
2 seconds
Flow rate data is displayed
4 seconds
%
%
%
%
%
•
See the section 8.2 Self-diagnostics function" for information on alarm numbers.